1. Articles from Olga Streltsova

    1-3 of 3
    1. Combined use of fluorescence cystoscopy and cross-polarization OCT for diagnosis of bladder cancer and correlation with immunohistochemical markers

      Combined use of fluorescence cystoscopy and cross-polarization OCT for diagnosis of bladder cancer and correlation with immunohistochemical markers

      The combined use of fluorescence cystoscopy and cross-polarization optical coherence tomography (CP OCT) with quantitative estimation of the OCT signal was assessed in 92 bladder zones. It demonstrated the diagnostic accuracy in detecting superficial bladder cancer of 93.6%, sensitivity 96.4%, specificity 92.1%, positive predictive value 87% and negative predictive value 97.9%. Quantitative estimation of OCT signal standard deviation in cross-polarization (CP OCT SD index) makes the visual criteria of CP OCT image assessment more objective. The level of CP OCT SD index for diagnosing superficial bladder cancer, including cancer in situ, was 4.32 dB and ...

      Read Full Article
    2. Cross-polarization optical coherence tomography for early bladder-cancer detection: statistical study

      Cross-polarization optical coherence tomography for early bladder-cancer detection: statistical study
      The capabilities of cross-polarization optical coherence tomography (CP OCT) for early bladder-cancer detection are assessed in statistical study and compared with the traditional OCT. Unlike the traditional OCT that demonstrates images only in copolarization, CP OCT acquires images in cross-polarization and copolarization simultaneously. 116 patients with localized flat suspicious lesions in the bladder were enrolled, 360 CP OCT images were obtained and analyzed. CP OCT demonstrated sensitivity 93.7% (vs. 81.2%, <0.0001), specificity 84% (vs. 70.0%, <0.001) and accuracy 85.3% (vs. 71.5%, <0.001) in detecting flat malignant bladder lesions, which is significantly better ...
      Read Full Article
    3. Monitoring oncological surgery using optical coherence tomography

      Monitoring oncological surgery using optical coherence tomography
      Detailed, real-time imaging allows for adjustment of surgical margins, thus sparing healthy tissue and increasing the likelihood of complete tumor removal. Development of local recurrence is one of the main causes of unsatisfactory long-term recovery prospects following cancer surgery. Determining the adequate balance between radical tumor removal and maximum preservation of the surrounding tissue is therefore very important for cancer management and, subsequently, the patient's quality of life. Rates of recurrence following surgical resection are appreciably high for a number of cancers. Following transurethral resection of bladder tumors (TURBT), they are reported to be as high as 40–80 ...
      Read Full Article
    1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) Nizhny Novgorod State Medical Academy
    2. (3 articles) Elena V. Zagaynova
    3. (3 articles) Natalia D. Gladkova
    4. (3 articles) Olga S. Streltsova
    5. (2 articles) Institute of Applied Physics
    6. (2 articles) Grigory V. Gelikonov
    7. (2 articles) Valentin M. Gelikonov
    8. (2 articles) Elena B. Kiseleva
    9. (2 articles) Maria M. Karabut
    10. (1 articles) Vladimir Zagaynov
    11. (1 articles) FDA
    12. (1 articles) Brian K. Courtney
    13. (1 articles) Conavi Medical Inc.
  3. Popular Articles

  4. Picture Gallery

    Monitoring oncological surgery using optical coherence tomography Cross-polarization optical coherence tomography for early bladder-cancer detection: statistical study Combined use of fluorescence cystoscopy and cross-polarization OCT for diagnosis of bladder cancer and correlation with immunohistochemical markers Conavi Medical and Japan Lifeline Announce MHLW Approval of Novasight Hybrid Intravascular Imaging System for Japanese Market Capsule Endomicroscopy for Visualization of the Small Intestine in EED Population in Pakistan Three-dimensional detection and quantification of defects in SiC by optical coherence tomography University of Illinois at Chicago Receives NIH Grant for Functional Tomography of Neurovascular Coupling Interactions in Healthy and Diseased Retinas Dyad Medical Receives NIH Grant for Software For OCT Analysis of Vascular Stents Oregon Health and Science University Receives NIH Grant for Application of Ultrahigh-Speed Long-Range Wide-Field OCT in Anterior Eye Diseases Optical coherence tomography and fractional flow reserve guided treatment of woven coronary artery anomaly presenting as acute myocardial infarction Impact of manual correction over automated segmentation of spectral domain optical coherence tomography The 360° circumferential opening of Schlemm's canal in normal individuals detected by enhanced depth imaging optical coherence tomography