Transit-time analysis based on delay-encoded beam shape for velocity vector quantification by spectral-domain Doppler optical coherence tomography
Explore Article opticsinfobase.org (Jan 11 2010) Doppler
We propose a transit-time based method to ascertain the azimuth angle of a velocity vector by spectral-domain Doppler optical coherence tomography (DOCT), so that three-dimensional (3-D) velocity vector can be quantified. A custom-designed slit plate with predetermined slit orientation is placed into the sample beam to create three delay-encoded sub-beams of different beam shape for sample probing. Based on the transit-time analysis for Doppler bandwidth, the azimuth angle within 90° range is evaluated by exploitation of the complex signals corresponding to three path length delays. 3-D velocity vector is quantified through further estimating of Doppler angle and flow velocity by ...
(Read Full Article)
-
Development of a high speed spectral domain optical coherence tomography system at 835 nm
Explore Article SPIE Digital Library (Dec 1 2009) Developmental Biology , Doppler
We develop a high speed multi-functional spectral domain (SD-OCT) system, using a broadband light source centered at 835nm and a custom-built spectrometer with a spectral resolution of 0.0674nm. After precise spectral calibration of the spectrometer, non-uniform discrete Fourier transform (NDFT) of the acquired spectral data is adopted for image reconstruction. In vivo imaging of human finger from volunteer at A-scan rate of 29 kHz with different reconstruction methods reveal that with the NDFT method, improved sensitivity fall-off especially at large depth is achieved in contrast to the conventional discrete Fourier transform (DFT) with interpolation method. And the phase information of ... (Read Full Article)
Comment on Article Mentions: Zhejiang University
-
Sinusoidal B-M method based spectral domain optical coherence tomography for the elimination of complex-conjugate artifact
Explore Article opticsinfobase.org (Sep 4 2009)
A high speed spectral domain optical coherence tomography based on the spatial sinusoidal phase modulation for the elimination of complex-conjugate artifact is presented, where sinusoidal phase modulation of reference arm (M scan) and transverse scanning of sample arm (B scan) are performed simultaneously (sinusoidal B-M method). Herein, the linear phase modulation of the reference arm in conventional linear B-M method is modified to sinusoidal phase modulation. The proposed sinusoidal B-M method relaxes the requirements on the phase-shifting mechanical system and avoids sensitivity fall-off along the transverse direction in contrast to the linear B-M method. A criterion for the relation between ...
(Read Full Article)
-
Development of a non-uniform discrete Fourier transform based high speed spectral domain optical coherence tomography system
Explore Article opticsinfobase.org (Jul 2 2009)
We develop a high speed spectral domain optical coherence tomography (SD-OCT) system based on a custom-built spectrometer and non-uniform discrete Fourier transform (NDFT) to realize minimized depth dependent sensitivity fall-off. After precise spectral calibration of the spectrometer, NDFT of the acquired spectral data is adopted for image reconstruction. The spectrometer is able to measure a wavelength range of about 138nm with a spectral resolution of 0.0674nm at central wavelength of 835nm, corresponding to an axial imaging range of 2.56mm in air. Zemax simulations and sensitivity fall-off measurements under two alignment states of the spectrometer are given. Both theoretical simulations and ...
(Read Full Article)
-
Common path endoscopic optical coherence tomography with outside path length compensation
Explore Article SPIE Digital Library (Jan 8 2008) Endoscopy
Yaliang Yang, Zhihua Ding, Jie Meng et al. Endoscopic optical coherence tomography (OCT) allowing high-resolution imaging of internal tissue is attractive for medical imaging. Fibre, fibre bundle or GRIN lens rod acting as endoscopic probe is placed in the sample arm of a Michelson interferometer in current endoscopic OCT systems, this arran ... [Proc. SPIE Int. Soc. Opt. Eng. 6826, 68261S (2008)] published Tue Jan 8, 2008. (Read Full Article)







Recent Comments
Eric Swanson » Jim Fujimoto video: Biophotonics and optical coherence tomography
Great video Jim!
dariemihaela » Gary S. Mintz
Dear Prof. Dr. Gary S. Mintz, You are an extraordinary expert in imaging, an intelligence ...
See all recent comments