1. Articles from Yin-Peng Huang

    1-3 of 3
    1. Quantitative spectroscopic comparison of the optical properties of mouse cochlea microstructures using optical coherence tomography at 1.06 µm and 1.3 µm wavelengths

      Quantitative spectroscopic comparison of the optical properties of mouse cochlea microstructures using optical coherence tomography at 1.06 µm and 1.3 µm wavelengths

      Currently, the cochlear implantation procedure mainly relies on using a hand lens or surgical microscope, where the success rate and surgery time strongly depend on the surgeon’s experience. Therefore, a real-time image guidance tool may facilitate the implantation procedure. In this study, we performed a systematic and quantitative analysis on the optical characterization of ex vivo mouse cochlear samples using two swept-source optical coherence tomography (OCT) systems operating at the 1.06-µm and 1.3-µm wavelengths. The analysis results demonstrated that the 1.06-µm OCT imaging system performed better than the 1.3-µm OCT imaging ...

      Read Full Article
    2. Effect of A-scan rate and interscan interval on optical coherence angiography

      Effect of A-scan rate and interscan interval on optical coherence angiography

      Optical coherence tomography angiography (OCTA) can provide rapid, volumetric, and noninvasive imaging of tissue microvasculature without the requirement of exogenous contrast agents. To investigate how A-scan rate and interscan time affected the contrast and dynamic range of OCTA, we developed a 1.06-µm swept-source OCT system enabling 100-kHz or 200-kHz OCT using two light sources. After system settings were carefully adjusted, almost the same detection sensitivity was achieved between the 100-kHz and 200-kHz modalities. OCTA of ear skin was performed on five mice. We used the variable interscan time analysis algorithm (VISTA) and the designated scanning protocol with OCTA ...

      Read Full Article
    3. A Generic Framework for Fourier-Domain Optical Coherence Tomography Imaging: Software Architecture and Hardware Implementations

      A Generic Framework for Fourier-Domain Optical Coherence Tomography Imaging: Software Architecture and Hardware Implementations

      Fourier-domain optical coherence tomography (FD-OCT), including spectral-domain OCT (SD-OCT) and swept-source OCT (SS-OCT), allows the volumetric imaging of the tissue architecture with a faster speed and higher detection sensitivity than does time-domain OCT. Although the hardware implementations of SD-OCT and SS-OCT are different, these technologies share very similar signal processing steps for image reconstruction. In this study, we developed hardware implementations and software architectures to design a generic framework for FD-OCT. For SD-OCT systems, an external synchronization approach was used to realize a data acquisition schematic similar to that used in SS-OCT by carefully managing the timing clocks in the ...

      Read Full Article
    1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) National Taiwan University
    2. (1 articles) University of Tsukuba
    3. (1 articles) Chang Gung University
    4. (1 articles) Medical University of Vienna
    5. (1 articles) University of Maryland
    6. (1 articles) University of Copenhagen
    7. (1 articles) Harbin Medical University
    8. (1 articles) Tianjin University
    9. (1 articles) Baylor College of Medicine
  3. Popular Articles

  4. Picture Gallery

    A Generic Framework for Fourier-Domain Optical Coherence Tomography Imaging: Software Architecture and Hardware Implementations Effect of A-scan rate and interscan interval on optical coherence angiography Quantitative spectroscopic comparison of the optical properties of mouse cochlea microstructures using optical coherence tomography at 1.06 µm and 1.3 µm wavelengths Peripapillary Vessel Density in Relation to Optic Disc Drusen: A Multimodal Optical Coherence Tomography Study Repeatability and reliability of semi-automated anterior segment-optical coherence tomography imaging compared to manual analysis in normal and keratoconus eyes Imaging of choroidal neovascular membrane by optical coherence tomography Angiography Image enhancement of wide-field retinal optical coherence tomography angiography by super-resolution angiogram reconstruction generative adversarial network Seven Fractures in Three Second Generation Drug Eluting Stents Implanted in the Right Coronary Artery Assessed by Using Optical Coherence Tomography Following the Beat: Imaging the Valveless Pumping Function in the Early Embryonic Heart Mirau-based line-field confocal optical coherence tomography for three-dimensional high-resolution skin imaging Optical Coherence Tomography Findings in Choroidal Melanoma-Associated Subretinal Fluid Evaluation of retinal vessel and perfusion density in migraine patients by optical coherence tomography angiography