    1. Birefringent tissue-mimicking phantom for polarization-sensitive optical coherence tomography imaging

      Birefringent tissue-mimicking phantom for polarization-sensitive optical coherence tomography imaging

      Significance: Tissue birefringence is an important parameter to consider when designing realistic, tissue-mimicking phantoms. Options for suitable birefringent materials that can be used to accurately represent tissue scattering are limited. Aim: To introduce a method of fabricating birefringent tissue phantoms with a commonly used material-polydimethylsiloxane (PDMS)-for imaging with polarization-sensitive optical coherence tomography (PS-OCT). Approach: Stretch-induced birefringence was characterized in PDMS phantoms made with varying curing ratios, and the resulting phantom birefringence values were compared with those of biological tissues. Results: We showed that, with induced birefringence levels up to 2.1 × 10 - 4, PDMS can be used to resemble ...

      Read Full Article
    2. Optimal number and orientation of anterior segment OCT images to measure ocular biometric parameters in angle closure eyes: the Chinese American Eye Study

      Optimal number and orientation of anterior segment OCT images to measure ocular biometric parameters in angle closure eyes: the Chinese American Eye Study

      Purpose: To assess the optimal number and orientation of anterior segment optical coherence tomography (AS-OCT) images for accurately measuring ocular biometric parameters in angle closure eyes. Methods: Subjects with angle closure, defined as >3 quadrants of non-visible pigmented trabecular meshwork on static gonioscopy, were selected from the Chinese American Eye Study. Mean angle opening distance (AOD500) was calculated using four images (0°-180°, 45°-225°, 90°-270° and 135°-315° meridians) from one eye per subject. Ten eyes from each quartile of AOD500 measurements were randomly selected for detailed 32-image analysis of 10 biometric parameters, including AOD500, iris curvature (IC ...

      Read Full Article
    3. Assessing accommodative presbyopic biometric changes of the entire anterior segment using single swept-source OCT image acquisitions

      Assessing accommodative presbyopic biometric changes of the entire anterior segment using single swept-source OCT image acquisitions

      Background/Objectives To evaluate biometric changes throughout the anterior chamber during accommodation and presbyopia using single image acquisition swept-source anterior-segment optical coherence tomography (AS-OCT). Subject/Methods Anterior-segment images were obtained using a new swept-source AS-OCT device (ANTERION, Heidelberg Engineering) from healthy volunteers ( n  = 71) across two centers in this prospective observational case series. In one image acquisition, cornea through posterior lens, including the ciliary muscle on both sides of the right eye, was imaged. Subjects undertook no accommodative effort and −1, −3, and −5 D of target vergence. Two-way repeated measures ANOVA modeling was performed for ciliary muscle measurements, lens ...

      Read Full Article
    4. Age- and refraction-related changes in anterior segment anatomical structures measured by swept-source anterior segment OCT

      Age- and refraction-related changes in anterior segment anatomical structures measured by swept-source anterior segment OCT

      Abstract Purpose: To assess the effects of age and refractive status on anterior segment anatomical structures, including the ciliary body, using a new swept-source anterior segment optical coherence tomography (AS-OCT) device. Methods: This prospective observational study included 63 healthy volunteers (mean age: 44.2 years). Images of the anterior segment were obtained using a new swept-source AS-OCT (ANTERION, Heidelberg Engineering GmbH, Heidelberg, Germany) with tracking and image averaging from the right eye of all participants. Repeatability as well as inter- and intra-observer reliability of biometric measurements were evaluated. The impact of image tracking and averaging on ciliary muscle measurements was ...

      Read Full Article
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (2 articles) University of Southern California
    2. (2 articles) UCLA
    3. (2 articles) Srinivas R. Sadda
    4. (2 articles) Heidelberg Engineering
    5. (1 articles) Vanderbilt University
    6. (1 articles) Northwestern University
    7. (1 articles) University College London
  3. Popular Articles

  4. Picture Gallery

    Age- and refraction-related changes in anterior segment anatomical structures measured by swept-source anterior segment OCT Assessing accommodative presbyopic biometric changes of the entire anterior segment using single swept-source OCT image acquisitions Optimal number and orientation of anterior segment OCT images to measure ocular biometric parameters in angle closure eyes: the Chinese American Eye Study Birefringent tissue-mimicking phantom for polarization-sensitive optical coherence tomography imaging Influence of scan direction on subfoveal choroidal vascularity index using optical coherence tomography Subthreshold Nanosecond Laser for Non-resolving Central Serous Chorioretinopathy: A Double-masked Sham-controlled Randomised Trial Optical Coherence Tomography Angiography (OCTA) to Assess Cardiac Output and Cerebral Perfusion at the Time of Children's Cardiac Surgery Recent advances in optical coherence tomography for anterior segment imaging in small animals and their clinical implications Intraoperative optical coherence tomography-guided donor corneal tissue assessment and preparation Peripapillary and fovea avascular zone optical coherence tomography angiography parameters in exfoliation glaucoma versus primary open-angle glaucoma versus healthy eyes Comparison of the proposed DCNN model with standard CNN architectures for retinal diseases classification Massachusetts General Hosptial Receives NIH Grant for Screening for Barrett's Esophagus Progressors with Multimodality Tethered Capsule Image-Guided Biopsy