1. Articles from Rebecca Zeng

    1-10 of 10
    1. Retinal microvasculature and vasoreactivity changes in hypertension using optical coherence tomography-angiography

      Retinal microvasculature and vasoreactivity changes in hypertension using optical coherence tomography-angiography

      Purpose: To evaluate the retinal vasculature and vasoreactivity of patients with hypertension (HTN) using spectral domain optical coherence tomography angiography (SD-OCTA). Methods: Patients with and without a diagnosis of HTN were included in this cross-sectional observational study. All eyes were imaged with SD-OCTA using 3 mm × 3 mm and 6 mm × 6 mm centered on both the fovea and optic disk. A second 6 mm × 6 mm scan was taken after a 30 s breath-hold. Vessel density (VD), vessel skeletonized density (VSD), and fractal dimension (FD) were calculated using customized MATLAB scripts. Vessel diameter index (VDI) was obtained by taking ...

      Read Full Article
    2. Widefield Swept-source OCT Angiography Metrics Associated with the Development of Diabetic Vitreous Hemorrhage A Prospective Study

      Widefield Swept-source OCT Angiography Metrics Associated with the Development of Diabetic Vitreous Hemorrhage A Prospective Study

      Objective: To investigate the association among widefield swept-source optical coherence tomography angiography (WF SS-OCTA) metrics and systemic parameters and the occurrence of vitreous hemorrhage (VH) in eyes with proliferative diabetic retinopathy (PDR). Design: Prospective, observational study. Participants: Fifty-five eyes from 45 adults with PDR, with no history of VH, followed for at least 3 months. Methods: All patients were imaged with WF SS-OCTA (Montage 15×15mm and HD-51 Line scan). Images were independently evaluated by two graders for quantitative and qualitative WF SS-OCTA metrics defined a priori. Systemic and ocular parameters and WF SS-OCTA metrics were screened using Least Absolute ...

      Read Full Article
    3. Detection of neovascularisation in the vitreoretinal interface slab using widefield swept-source optical coherence tomography angiography in diabetic retinopathy

      Detection of neovascularisation in the vitreoretinal interface slab using widefield swept-source optical coherence tomography angiography in diabetic retinopathy

      Aims To compare the efficacy of diabetic retinal neovascularisation (NV) detection using the widefield swept-source optical coherence tomography angiography (WF SS-OCTA) vitreoretinal interface (VRI) Angio slab and SS-OCT VRI Structure slab. Methods A prospective, observational study was performed at Massachusetts Eye and Ear from January 2019 to June 2020. Patients with proliferative diabetic retinopathy (PDR), patients with non-proliferative diabetic retinopathy and patients with diabetes but without diabetic retinopathy were included. All patients were imaged with WF SS-OCTA using the 12×12 mm Angio scan protocol centred on the fovea and optic disc. The en-face SS-OCTA VRI Angio slab and SS-OCT ...

      Read Full Article
    4. A quantitative comparison of four optical coherence tomography angiography devices in healthy eyes

      A quantitative comparison of four optical coherence tomography angiography devices in healthy eyes

      Purpose Optical coherence tomography angiography (OCT-A) is a novel imaging modality for the diagnosis of chorioretinal diseases. A number of FDA-approved OCT-A devices are currently commercially available, each with unique algorithms and scanning protocols. Although several published studies have compared different combinations of OCT-A machines, there is a lack of agreement on the consistency of measurements across OCT-A devices. Therefore, we conducted a prospective quantitative comparison of four available OCT-A platforms. Methods Subjects were scanned on four devices: Optovue RTVue-XR, Heidelberg Spectralis OCT2 module, Zeiss Plex Elite 9000 Swept-Source OCT, and Topcon DRI-OCT Triton Swept-Source OCT. 3 mm × 3 mm ...

      Read Full Article
    5. Detection of Venous Loops in Diabetic Retinopathy using Widefield Swept-Source Optical Coherence Tomography Angiography

      Detection of Venous Loops in Diabetic Retinopathy using Widefield Swept-Source Optical Coherence Tomography Angiography

      Purpose : Retinal venous loops (RVL) are rare manifestations of diabetic retinopathy (DR) usually identified by color fundus photography. The prevalence and its predictive value reported in the literature may be underestimated due to the limitations of detection techniques. This study investigated the prevalence of RVL and their associated microvascular changes using widefield swept-source optical coherence tomography angiography (WF SS-OCTA). Methods : In this retrospective, observational study at Mass Eye and Ear from December 2018 to December 2019, diabetic patients with proliferative diabetic retinopathy (PDR), non-proliferative diabetic retinopathy (NPDR) and without DR were included. All patients were imaged with a WF SS-OCTA ...

      Read Full Article
    6. Comparison of widefield swept-source optical coherence tomography angiography with ultra-widefield colour fundus photography and fluorescein angiography for detection of lesions in diabetic retinopathy

      Comparison of widefield swept-source optical coherence tomography angiography with ultra-widefield colour fundus photography and fluorescein angiography for detection of lesions in diabetic retinopathy

      Aims To compare widefield swept-source optical coherence tomography angiography (WF SS-OCTA) with ultra-widefield colour fundus photography (UWF CFP) and fluorescein angiography (UWF FA) for detecting diabetic retinopathy (DR) lesions. Methods This prospective, observational study was conducted at Massachusetts Eye and Ear from December 2018 to October 2019. Proliferative DR, non-proliferative DR and diabetic patients with no DR were included. All patients were imaged with a WF SS-OCTA using a Montage 15×15 mm scan. UWF CFP and UWF FA were taken by a 200°, single capture retinal imaging system. Images were independently evaluated for the presence or absence of DR ...

      Read Full Article
    7. Different Scan Protocols Affect the Detection Rates of Diabetic Retinopathy Lesions by Wide-field Swept-Source Optical Coherence Tomography Angiography

      Different Scan Protocols Affect the Detection Rates of Diabetic Retinopathy Lesions by Wide-field Swept-Source Optical Coherence Tomography Angiography

      Purpose To compare different scan protocols of wide field swept-source optical coherence tomography angiography (SS-OCTA) for the detection of diabetic retinopathy (DR) lesions. Design Comparison of diagnostic approaches. Methods A prospective, observational study was conducted at Mass Eye and Ear from December 2018 to July 2019. Proliferative diabetic retinopathy (PDR), non-proliferative diabetic retinopathy (NPDR) and diabetic patients without DR were included. All patients were imaged with a SS-OCTA using following scan protocol: Angio 3mm×3mm centered on fovea, Angio 6mm×6mm centered on fovea and optic disc, Montage 15mm×9mm and Angio 12mm×12mm centered on fovea and optic disc ...

      Read Full Article
    8. Detection of retinal microvascular changes in von Hippel-Lindau disease using optical coherence tomography angiography

      Detection of retinal microvascular changes in von Hippel-Lindau disease using optical coherence tomography angiography

      Purpose Von Hippel-Lindau (VHL) disease is a hereditary disorder that can lead to ophthalmic manifestations, including retinal capillary hemangioma (RCH). The diagnosis of RCH is often guided by wide-field fluorescein angiography. In some cases, optical coherence tomography angiography (OCT-A) serves as a non-invasive alternative to FA. Herein, we used OCT-A to examine the macular microvasculature in patients with VHL disease. Subjects Subjects were selected from patients with a diagnosis of VHL. The control group included eyes without retinal diagnosis from patients with an episode of unilateral retinal detachment or trauma and age ≤ 50 years old. Methods Subjects were scanned on ...

      Read Full Article
    9. Imaging Artifacts and Segmentation Errors With Wide-Field Swept-Source Optical Coherence Tomography Angiography in Diabetic Retinopathy

      Imaging Artifacts and Segmentation Errors With Wide-Field Swept-Source Optical Coherence Tomography Angiography in Diabetic Retinopathy

      Purpose : To analyze imaging artifacts and segmentation errors with wide-field swept-source optical coherence tomography angiography (SS-OCTA) in diabetic retinopathy (DR). Methods : We conducted a prospective, observational study at Massachusetts Eye and Ear from December 2018 to March 2019. Proliferative diabetic retinopathy (PDR), nonproliferative diabetic retinopathy (NPDR), diabetic patients with no diabetic retinopathy (DR), and healthy control eyes were included. All patients were imaged with a SS-OCTA and the Montage Angio (15 × 9 mm) was used for analysis. Images were independently evaluated by two graders using the motion artifact score (MAS). All statistical analyses were performed using SPSS 25.0 and ...

      Read Full Article
    10. Quantitative Comparison Of Microvascular Metrics On Three Optical Coherence Tomography Angiography Devices In Chorioretinal Disease

      Quantitative Comparison Of Microvascular Metrics On Three Optical Coherence Tomography Angiography Devices In Chorioretinal Disease

      Purpose: Optical coherence tomography angiography (OCT-A) has emerged as a novel tool for the non-invasive imaging and evaluation of the retinal microvasculature. There is little existing literature that compares OCT-A microvasculature metrics across different OCT-A devices in chorioretinal diseases. Herein, we examined these metrics on three available OCT-A platforms. Patients and methods: All subjects were scanned on each of three OCT-A devices: Optovue Avanti Angiovue, Topcon DRI-OCT Triton Swept-Source OCT, and Zeiss Cirrus 5000-HD-OCT Angioplex. Two investigators independently measured foveal avascular zone (FAZ) area. Superficial capillary plexus (SCP) and deep capillary plexus (DCP) vessel densities (VD) were calculated from binarized ...

      Read Full Article
    1-10 of 10
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (9 articles) Massachusetts Eye and Ear Infirmary
    2. (9 articles) Harvard University
    3. (3 articles) Visionix
    4. (2 articles) Wenzhou Medical College
    5. (2 articles) Carl Zeiss Meditec
    6. (2 articles) Topcon Medical Systems
    7. (1 articles) Boston University
    8. (1 articles) Johns Hopkins University
    9. (1 articles) National Institutes of Health
    10. (1 articles) Heidelberg Engineering
    11. (1 articles) FDA
    12. (1 articles) University of Rochester
    13. (1 articles) Notal Vision
    14. (1 articles) Topcon Medical Systems
    15. (1 articles) Tomey Corporation
  3. Popular Articles

  4. Picture Gallery

    Quantitative Comparison Of Microvascular Metrics On Three Optical Coherence Tomography Angiography Devices In Chorioretinal Disease Imaging Artifacts and Segmentation Errors With Wide-Field Swept-Source Optical Coherence Tomography Angiography in Diabetic Retinopathy Detection of retinal microvascular changes in von Hippel-Lindau disease using optical coherence tomography angiography Different Scan Protocols Affect the Detection Rates of Diabetic Retinopathy Lesions by Wide-field Swept-Source Optical Coherence Tomography Angiography Comparison of widefield swept-source optical coherence tomography angiography with ultra-widefield colour fundus photography and fluorescein angiography for detection of lesions in diabetic retinopathy Detection of Venous Loops in Diabetic Retinopathy using Widefield Swept-Source Optical Coherence Tomography Angiography A quantitative comparison of four optical coherence tomography angiography devices in healthy eyes Detection of neovascularisation in the vitreoretinal interface slab using widefield swept-source optical coherence tomography angiography in diabetic retinopathy Widefield Swept-source OCT Angiography Metrics Associated with the Development of Diabetic Vitreous Hemorrhage A Prospective Study Retinal microvasculature and vasoreactivity changes in hypertension using optical coherence tomography-angiography Cascade Optical Coherence Tomography (C-OCT) for Surface Form Metrology of - ProQuest Comparison of Anterior Segment Measurements with a New Multifunctional Unit and Five Other Devices