1. Articles from Pasquale Viggiano

    1-8 of 8
    1. Retinal vascular metrics difference by comparison of two image acquisition modes using a novel OCT angiography prototype

      Retinal vascular metrics difference by comparison of two image acquisition modes using a novel OCT angiography prototype

      Purpose To assess the different impact of two enface OCTA image simultaneously acquired by means of a new prototype of Spectral-Domain Optical Coherence Tomography Angiography (SD-OCTA) on quantitative retinal vascular metrics. Methods In this prospective observational cross-sectional study 28 healthy subjects were enrolled. Macular (3x3 mm) OCTA images were acquired for all participants using Solix Fullrange OCT (Optovue Inc, Freemont CA, USA). The main outcome measurements were: Perfusion density (PD), vessel length density (VLD), and vessel diameter index (VDI) of both superficial capillary plexus (SCP) and deep capillary plexus (DCP), and choriocapillaris (CC) total flow-deficits area. Quantitative retinal vascular metrics ...

      Read Full Article
    2. Optical Coherence Tomography Angiography in Macular Neovascularization: A Comparison Between Different OCTA Devices

      Optical Coherence Tomography Angiography in Macular Neovascularization: A Comparison Between Different OCTA Devices

      Purpose : The purpose of this study is to compare the ability of 3 optical coherence tomography angiography (OCTA) devices to measure lesion area in patients with macular neovascularization (MNV) with type 1, 2 and mixed neovascularization (NV). Methods : OCTA, fluorescein angiography (FA), indocyanine green angiography (ICGA), and structural optical coherence tomography (OCT) were performed. NV lesion area measurements were performed by two graders. Results : Twenty-eight eyes were included: 20 with NV were classified as type 1, 6 as type 2, and 2 as mixed type. AngioVue and Spectralis detected the NV in 26 out of 28 eyes (92.8%). The ...

      Read Full Article
    3. Changes in Iris Perfusion Following Scleral Buckle Surgery for Rhegmatogenous Retinal Detachment: An Anterior Segment Optical Coherence Tomography Angiography (AS-OCTA) Study

      Changes in Iris Perfusion Following Scleral Buckle Surgery for Rhegmatogenous Retinal Detachment: An Anterior Segment Optical Coherence Tomography Angiography (AS-OCTA) Study

      Purpose: To investigate iris vasculature changes following scleral buckling (SB) surgery in eyes with rhegmatogenous retinal detachment (RRD) with anterior-segment (AS) optical coherence tomography angiography (OCTA). Methods: In this prospective study, enrolled subjects were imaged with an SS-OCTA system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). Image acquisition of the iris was obtained using an AS lens and a manual focusing adjustment in the iris using the retina imaging software. The quantitative analysis was performed in eight different iris regions: (i) superior, (ii) supero-temporal, (iii) supero-nasal, (iv) nasal, (v) temporal, (vi) inferior, (vii) infero-temporal, (viii) infero nasal ...

      Read Full Article
    4. Widefield topographical analysis of the retinal perfusion and neuroretinal thickness in healthy eyes: a pilot study

      Widefield topographical analysis of the retinal perfusion and neuroretinal thickness in healthy eyes: a pilot study

      Purpose In this pilot study we reported variation of superficial (SCP) and deep (DCP) capillary plexuses flow in macular and near/mid periphery regions in healthy subjects using widefield swept source-optical coherence tomography angiography (SS-OCTA). Methods In this prospective, cross-sectional study, enroled subjects were imaged with an SS-OCTA system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). OCTA scans were taken in primary and extremes of gaze and a montage was automatically created. Quantitative analysis was performed in the macular and peripheral regions. In addition, SCP and DCP variables were further investigated in distinct fields within these three ...

      Read Full Article
    5. In Vivo Mapping of the Choriocapillaris in High myopia: a Widefield Swept Source Optical Coherence Tomography Angiography

      In Vivo Mapping of the Choriocapillaris in High myopia: a Widefield Swept Source Optical Coherence Tomography Angiography

      To report variation of choriocapillaris (CC) flow in widefield in high in myopic subjects compared with an age-matched normal control group using ultra widefield optical coherence tomography angiography (UW-OCTA). This is a Prospective, cross-sectional study. Thirty high myopia subjects and fifty healthy subjects were enrolled. Healthy and high myopia subjects were imaged with the SS-OCTA system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). For each eye, five 12 × 12-mm OCTA volume scans were acquired. The en face CC images were then exported to imageJ and a semi-automated algorithm was used for subsequent quantitative analysis. The main outcome ...

      Read Full Article
    6. Early retinal flow changes after vitreoretinal surgery in idiopathic epiretinal membrane using swept source optical coherence tomography angiography

      Early retinal flow changes after vitreoretinal surgery in idiopathic epiretinal membrane using swept source optical coherence tomography angiography

      (1) Background: The aim of this observational cross-sectional work was to investigate early retinal vascular changes in patients undergoing idiopathic epiretinal membrane (iERM) surgery using swept source optical coherence tomography angiography (SS-OCTA); (2) Methods: 24 eyes of 24 patients who underwent vitrectomy with internal limiting membrane (ILM) peeling were evaluated pre- and postoperatively using SS-OCTA system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). For each eye, five 6x6-mm OCTA volume scans were acquired by two observers independently. The en face images of superficial capillary plexus (SCP) were then exported to imageJ and a semi-automated algorithm was used ...

      Read Full Article
    7. Eyelashes Artifact in Ultra-Widefield Optical Coherence Tomography Angiography

      Eyelashes Artifact in Ultra-Widefield Optical Coherence Tomography Angiography

      BACKGROUND AND OBJECTIVE: To describe the presence of eyelashes artifact in ultra-widefield swept-source optical coherence tomography angiography (SS-OCTA) images. PATIENTS AND METHODS: In this prospective, cross-sectional study, 52 healthy, young subjects were imaged with the SS-OCTA system. OCTA scans were taken in primary and extremes of gaze, and a montage was automatically created. The en face choriocapillaris images were then exported, and a semi-automated algorithm was used for subsequent quantitative analysis. RESULTS: The authors noted the presence of some linear regions of reduced brightness, which were assumed to represent a shadow effect due to patient eyelashes. In order to quantify ...

      Read Full Article
    8. In Vivo Mapping of the Choriocapillaris in Healthy Eyes: a Widefield Swept Source Optical Coherence Tomography Angiography Study

      In Vivo Mapping of the Choriocapillaris in Healthy Eyes: a Widefield Swept Source Optical Coherence Tomography Angiography Study

      Purpose To report variation of choriocapillaris (CC) flow in peripapillary, macular and near/mid periphery regions in healthy subjects using widefield swept source optical coherence tomography angiography (SS-OCTA). Design Prospective, cross-sectional study. Subjects Fifty healthy subjects. Methods Healthy young subjects were imaged with the SS-OCTA system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). OCTA scans were taken in primary and extremes of gaze and a montage was automatically created. The en face CC images were then exported to imageJ and a semi-automated algorithm was used for subsequent quantitative analysis. Main outcome measures Quantitative analysis of the CC ...

      Read Full Article
    1-8 of 8
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (5 articles) Carl Zeiss Meditec
    2. (1 articles) Kyoto University Graduate School of Medicine
    3. (1 articles) Samsung
    4. (1 articles) Johns Hopkins University
    5. (1 articles) National Institutes of Health
    6. (1 articles) Sungkyunkwan University
    7. (1 articles) University of São Paulo
    8. (1 articles) Massachusetts Institute of Technology
    9. (1 articles) L V Prasad Eye Institute
    10. (1 articles) Gong Je Seong
    11. (1 articles) Chan Yun Kim
    12. (1 articles) James G. Fujimoto
  3. Popular Articles

  4. Picture Gallery

    In Vivo Mapping of the Choriocapillaris in Healthy Eyes: a Widefield Swept Source Optical Coherence Tomography Angiography Study Eyelashes Artifact in Ultra-Widefield Optical Coherence Tomography Angiography Early retinal flow changes after vitreoretinal surgery in idiopathic epiretinal membrane using swept source optical coherence tomography angiography In Vivo Mapping of the Choriocapillaris in High myopia: a Widefield Swept Source Optical Coherence Tomography Angiography Widefield topographical analysis of the retinal perfusion and neuroretinal thickness in healthy eyes: a pilot study Changes in Iris Perfusion Following Scleral Buckle Surgery for Rhegmatogenous Retinal Detachment: An Anterior Segment Optical Coherence Tomography Angiography (AS-OCTA) Study Optical Coherence Tomography Angiography in Macular Neovascularization: A Comparison Between Different OCTA Devices Retinal vascular metrics difference by comparison of two image acquisition modes using a novel OCT angiography prototype Factors Associated with Changes in Retinal Layers Following Acute Optic Neuritis: A Longitudinal Study Using Optical Coherence Tomography Relationship between N95 Amplitude of Pattern Electroretinogram and Optical Coherence Tomography Angiography in Open-Angle Glaucoma Historic Effort to 'End Blindness" Marks a Major Milestone with Leading Scientist Recognized for Pioneering Work at VIP Ceremony Featuring Tribute to Ruth Bader Ginsburg Healing and early stent coverage after ultrathin strut biodegradable polymer‐coated sirolimus‐eluting stent implantation: SiBi optical coherence tomography study