1. Articles from Min-Ji Kang

    1-2 of 2
    1. Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross–sectional study

      Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross–sectional study

      Background To evaluate the accuracy of biometric measurements by a swept-source optical coherence tomography (SS–OCT) based biometry for intraocular lens (IOL) power calculation. Methods This retrospective observational study enrolled 431 patients undergoing cataract surgery. The charts were reviewed to investigate the failure rate of axial length (AL) measurement of the SS–OCT biometer, partial coherence interferometry (PCI), and A–scan ultrasonography (US) according to cataract type and severity. AL and keratometry in 164 eyes with the same IOL inserted were measured using the SS–OCT biometer, PCI, and A–scan US. The SRK/T formula was used to calculate ...

      Read Full Article
    2. Predictive accuracy of partial coherence interferometry and swept-source optical coherence tomography for intraocular lens power calculation

      Predictive accuracy of partial coherence interferometry and swept-source optical coherence tomography for intraocular lens power calculation

      The purpose of this study is to compare the predictive accuracy of intraocular lens (IOL) calculations made with partial coherence interferometry (PCI, IOLMaster, version 5) and swept-source optical coherence tomography (SS-OCT, Argos). Axial length (AL), mean keratometry value (K), and anterior chamber depth (ACD) were obtained using PCI and SS-OCT optical biometers. Intraocular lens (IOL) power calculations were made using the Barret-Universal II, Haigis, Hoffer Q, SRK/T, and T2 formulas and compared the predictive accuracy between biometers. In 153 eyes (153 patients), axial length measurements made with PCI (24.65 ± 2.35 mm) and SS-OCT (24.62 ± 2.29 ...

      Read Full Article
    1-2 of 2
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (1 articles) UC Davis
    2. (1 articles) Robert J. Zawadzki
    3. (1 articles) Mehdi Azimipour
    4. (1 articles) John S. Werner
    5. (1 articles) Ravi S. Jonnal
  3. Popular Articles

  4. Picture Gallery

    Predictive accuracy of partial coherence interferometry and swept-source optical coherence tomography for intraocular lens power calculation Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross–sectional study Optoretinography: optical measurements of human cone and rod photoreceptor responses to light Nodular skin lesions: correlation of reflectance confocal microscopy (RCM) and optical coherence tomography (OCT) features OCT and Ophthalmology in the Age of Artificial Intelligence, Tuesday Oct 8, 2019 1:00P EDT Compensation for the Influence of Fluctuations in the Distance to the Object During Noncontact Probing in Spectral Domain Optical Coherence Tomography Pattern electroretinogram changes in patients with primary open-angle glaucoma in correlation with visual field and optical coherence tomography changes Objective evaluation of proliferative diabetic retinopathy using optical coherence tomography Repeatability of Cornea and Sublayer Thickness Measurements Using Optical Coherence Tomography in Corneas of Anomalous Refractive Status Endoscopic Optical Coherence Tomography for Assessing Inhalation Airway Injury: A Technical Review Optical coherence tomography diagnostic signs in posterior uveitis Optical coherence tomography en face analysis of the posterior vitreous reveal topographic relationships between premacular bursa, prevascular fissures and cisterns