1. Articles from Hon Shing Ong

    1-3 of 3
    1. Optical Coherence Tomography Angiography Imaging to monitor Anti-VEGF treatment of Corneal Vascularization in a Rabbit Mode

      Optical Coherence Tomography Angiography Imaging to monitor Anti-VEGF treatment of Corneal Vascularization in a Rabbit Mode

      Optical coherence tomography angiography (OCTA) is a well-established non-invasive retinal vascular imaging technique. It has been recently adapted to image the anterior segment and has shown good potential to image corneal vascularisation. The purpose of the study is to evaluate the usefulness of OCTA to monitor regression of corneal vessels following anti-VEGF (vascular endothelial growth factor) treatment using a previously established corneal vascularisation rabbit model. The regression of vessels following the treatment with aflibercept and ranibizumab anti-VEGFs using both topical instillation and sub-conjunctival injection was quantified using OCTA and compared with ICGA (indocyanine green angiography). Overall vessel density measurements using ...

      Read Full Article
    2. Vessel density and En-face segmentation of optical coherence tomography angiography to analyse corneal vascularisation in an animal model

      Vessel density and En-face segmentation of optical coherence tomography angiography to analyse corneal vascularisation in an animal model

      Background Optical coherence tomography angiography (OCTA) is a novel non-invasive angiography technology that has recently been extensively studied for its utility in anterior segment imaging. In this study, we compared a split-spectrum amplitude decorrelation angiography (SSADA) OCTA and an optical micro-angiography (OMAG SD) OCTA system to current angiographic technique, indocyanine green angiography (ICGA), to assess corneal vascularisation in an animal model. Methods We imaged 16 rabbits, (one eye per animal) with corneal vascularisation using SSADA OCTA (AngioVue; Optovue Inc., USA), OMAG OCTA (Angioscan; RS-3000 Nidek Co. Ltd., Japan) and ICGA in the same region of interest of the cornea at ...

      Read Full Article
    3. Quantification of the Posterior Cornea Using Swept Source Optical Coherence Tomography

      Quantification of the Posterior Cornea Using Swept Source Optical Coherence Tomography

      Purpose : We define optical coherence tomography (OCT) measurement parameters of the corneal endothelium/Descemet's membrane (DM) complex and peripheral transition zone (TZ) and describe these measurements in an ethnically Chinese population. Methods : OCT images of the anterior segment and iridocorneal angle were obtained from 129 healthy Chinese subjects (129 eyes), aged 40 to 81 years. The scleral spur (SS) and Schwalbe's line (SL) were identified in each image. Endothelium/DM diameter, referred to as endothelial arc length (EAL), is the SL-to-SL distance. The SS-to-SL distance encompasses the TZ and trabecular meshwork (TM). Since the TZ cannot be visualized ...

      Read Full Article
    1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) Singapore Eye Research Institute
    2. (3 articles) Jodhbir S. Mehta
    3. (1 articles) Optovue
    4. (1 articles) Nidek
    5. (1 articles) UCLA
    6. (1 articles) University of Groningen
    7. (1 articles) University of Wisconsin
    8. (1 articles) University of St. Andrews
    9. (1 articles) Duke University
    10. (1 articles) Kishan Dholakia
    11. (1 articles) Cynthia A. Toth
    12. (1 articles) Optovue
    13. (1 articles) Leica
    14. (1 articles) Heidelberg Engineering
  3. Popular Articles

  4. Picture Gallery

    Quantification of the Posterior Cornea Using Swept Source Optical Coherence Tomography Vessel density and En-face segmentation of optical coherence tomography angiography to analyse corneal vascularisation in an animal model Optical Coherence Tomography Angiography Imaging to monitor Anti-VEGF treatment of Corneal Vascularization in a Rabbit Mode Long-Term Arterial Remodeling After Bioresorbable Scaffold Implantation 4-Year Follow-up of Quantitative Coronary Angiography, Histology and Optical Coherence Tomography Visualization of Bacterial Colonization and Cellular Layers in a Gut-on-a-Chip System Using Optical Coherence Tomography Optical Coherence Tomography Measurements as Potential Imaging Biomarkers for Parkinson's Disease: A Systematic Review and Meta-analysis Use of ultra-wide field retinal imaging and optical coherence tomography angiography in the diagnosis of incomplete Susac syndrome Repeatability and agreement of total corneal and sublayer pachymetry with two different algorithms of fourier-domain optical coherence tomography in myopic and post photorefractive keratectomy eyes Monitoring Response to Platelet-Rich Plasma in Patients with Alopecia Areata with Optical Coherence Tomography: A Case Series NONPERFUSION AREA QUANTIFICATION IN BRANCH RETINAL VEIN OCCLUSION: A WIDEFIELD OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY STUDY Nonperfusion Assessment in Retinal Vein Occlusion: Comparison between Ultra-Widefield Fluorescein Angiography and Widefield OCT-Angiography Anatomical Location of the Raphe and Extended Raphe in the Human Retina: Implications for Assessment of the Optic Nerve with OCT