1. Articles from Bihua Tang

    1-3 of 3
    1. Feature Of The Week 07/22/2019: Tsinghua University Demonstrates A “Sparse Sampled” Smart CCD Camera for Compressed Sensing Optical Coherence Tomography.

      Feature Of The Week 07/22/2019: Tsinghua University Demonstrates A “Sparse Sampled” Smart CCD Camera for Compressed Sensing Optical Coherence Tomography.

      Optical coherence tomography (OCT) is a promising imaging technique in medicine and biology, which allows for obtaining high-resolution, cross-sectional images of biological tissues. In the past decade, the imaging speed of OCT is consistently increasing, and currently OCT can acquire three-dimensional (3D) images in real time with imaging speed up to 10-MHz A-scan rate. With such a high imaging rate, OCT system has to acquire a large amount of data, which is too massive for data transmission and storage. Compressed sensing (CS) technique is a powerful method to solve this problem. It exploits the sparsity property of the signal and ...

      Read Full Article
    2. Compressed sensing spectral domain optical coherence tomography with a hardware sparse-sampled camera

      Compressed sensing spectral domain optical coherence tomography with a hardware sparse-sampled camera

      We present a sparse-sampled camera for compressed sensing spectral domain optical coherence tomography (CS SD-OCT), which is mainly composed of a novel mask with specially designed coating and a commercially available CCD camera. The sparse-sampled camera under-samples the SD-OCT spectrum in hardware, thus reduces the acquired image data and can achieve faster A-scan speed than conventional CCD camera with the same pixel number. Compared with a conventional SD-OCT system, the CS SD-OCT system equipped with the sparse-sampled camera has better fall-off and SNR performance. CS-OCT imaging of bio-tissue is also demonstrated.

      Read Full Article
    3. Conjugate transformation for dispersion compensation in optical coherence tomography imaging

      Conjugate transformation for dispersion compensation in optical coherence tomography imaging

      In optical coherence tomography (OCT), the sample dispersion tends to increase the signal width and hence lower down the resolution, resulting in serious image quality degradation, especially for imaging over a large depth range or media with large dispersion coefficient. In this letter, instead of the conventional Fourier transformation for dispersion compensation that can compensate the image only ideally at a certain depth, a novel transformation, as called conjugate transformation, is proposed to achieve high resolution at all depth by utilizing the conjugate function of the signal itself as an optimized integral kernel. A large dispersion media of ZnSe is ...

      Read Full Article
    1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) Tsinghua University
    2. (3 articles) Chengming Wang
    3. (3 articles) Ping Xue
    4. (3 articles) Ning Zhang
    5. (2 articles) Nanjing University of Science and Technology
  3. Popular Articles

  4. Picture Gallery

    Conjugate transformation for dispersion compensation in optical coherence tomography imaging Compressed sensing spectral domain optical coherence tomography with a hardware sparse-sampled camera Feature Of The Week 07/22/2019: Tsinghua University Demonstrates A “Sparse Sampled” Smart CCD Camera for Compressed Sensing Optical Coherence Tomography. CT texture analysis of vulnerable plaques on optical coherence tomography Peri-stent contrast staining after ultrathin, biodegradable polymer sirolimus-eluting stent implantation: findings from optical coherence tomography and coronary angioscopy An optimized segmentation and quantification approach in microvascular imaging for OCTA-based neovascular regression monitoring Postdoctoral Research Fellowship at Nanyang Technological University, Singapore The Macular Choriocapillaris Flow in Glaucoma and Within-Day Fluctuations: An Optical Coherence Tomography Angiography Study Impact of Optical Coherence Tomography Imaging on Decision-Making During Percutaneous Coronary Intervention in Patients Presented With Acute Coronary Syndromes Time course of collateral vessel formation after retinal vein occlusion visualized by OCTA and elucidation of factors in their formation Peripapillary Retinal Nerve Fiber Layer and Ganglion Cell-Inner Plexiform Layer Changes on Optical Coherence Tomography in Patients with Unilateral Hypertensive Cytomegalovirus Anterior Uveitis Utility of spectral domain OCT in differentiating optic disc drusen from papilledema in children