    1. Early and mid-term vascular responses to optical coherence tomography guided everolimus-eluting stent implantation in stable coronary artery disease

      Early and mid-term vascular responses to optical coherence tomography guided everolimus-eluting stent implantation in stable coronary artery disease

      Background Analysis of pooled clinical data has shown the safety of 3 months of dual antiplatelet therapy (DAPT) with everolimus-eluting cobalt–chromium stents (Co-Cr EESs). This study evaluated early and mid-term vascular responses to Co-Cr EESs in patients with stable coronary artery disease (CAD). Methods The MECHANISM-Elective trial (NCT02014818) is a multicenter optical coherence tomography (OCT) registry. Enrolled patients were evaluated by OCT immediately after EES implantation (post), were prospectively allocated to either 1 month (n = 50) or 3 months (n = 50) OCT follow-up, and then received a 12 months OCT evaluation. The incidences of intrastent thrombus (IS-Th) and irregular ...

      Read Full Article
    2. Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study)

      Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study)

      The use of cobalt–chromium everolimus-eluting stents (CoCr-EES) for ST-segment elevation myocardial infarction (STEMI) reduces the incidence of stent thrombosis compared with bare metal stents, and a substantial difference is apparent in the initial 2 weeks. However, vascular behavior during this early period remains unclear. This was a prospective study (MECHANISM-AMI-2W) to investigate early vascular responses in STEMI patients immediately after CoCr-EES implantation and at 2-week follow-up using frequency domain-optical coherence tomography (FD-OCT). The study enrolled 52 patients (age 63.7 ± 11.7 years, male 85.0%), of whom 44 patients were available for complete serial FD-OCT analyses. Both % uncovered ...

      Read Full Article
    1-2 of 2
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (2 articles) Kobe University Graduate School of Medicine
    2. (2 articles) Toshiro Shinke
    3. (2 articles) Hiromasa Otake
    4. (1 articles) Wakayama Medical University
    5. (1 articles) Iwate Medical University
    6. (1 articles) Hiroyuki Tanaka
    7. (1 articles) Junya Shite
    8. (1 articles) Takashi Akasaka
    9. (1 articles) Takashi Kubo
    10. (1 articles) Tomonori Itoh
    11. (1 articles) Yonsei University
    12. (1 articles) University of Kent
    13. (1 articles) Tianjin University
    14. (1 articles) University College London
    15. (1 articles) UCSD
    16. (1 articles) Adrian G. Podoleanu
    17. (1 articles) Jung-Sun Kim
    18. (1 articles) Dong Hoon Choi
    19. (1 articles) Giovanni J. Ughi
    20. (1 articles) Gentuity
  3. Popular Articles

  4. Picture Gallery

    Early vascular responses to everolimus-eluting cobalt–chromium stent in the culprit lesions of st-elevation myocardial infarction: results from a multicenter prospective optical coherence tomography study (MECHANISM-AMI 2-week follow-up study) Early and mid-term vascular responses to optical coherence tomography guided everolimus-eluting stent implantation in stable coronary artery disease Quantifying the Separation Between the Retinal Pigment Epithelium and Bruch's Membrane using Optical Coherence Tomography in Patients with Inherited Macular Degeneration Texture preservation and speckle reduction in poor optical coherence tomography using the convolutional neural network Research Assistant in Optical Coherence Tomography (OCT) to Image the Eye at University of Kent Comparison of retinal vessel diameter measurements from swept-source OCT angiography and adaptive optics ophthalmoscope Chronic Stent Recoil in Severely Calcified Coronary Artery Lesions. A Serial Optical Coherence Tomography Study Migrated remnant bioresorbable scaffolds in a left main bifurcation lesion: Insights from optical coherence tomography Longitudinal Monitoring of Flow-Diverting Stent Tissue Coverage After Implant in a Bifurcation Model Using Neurovascular High-Frequency Optical Coherence Tomography Foveal crack sign: an optical coherence tomography sign preceding macular hole after vitrectomy for rhegmatogenous retinal detachment Forward genetic analysis using OCT screening identifies Sfxn3 mutations leading to progressive outer retinal degeneration in mice Optical coherence tomography characteristics of taxane-induced macular edema and other multimodal imaging findings