    1. Coextensive synchronized SLO-OCT with adaptive optics for human retinal imaging

      Coextensive synchronized SLO-OCT with adaptive optics for human retinal imaging

      We describe the details of a multimodal retinal imaging system which combines adaptive optics (AO) with an integrated scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT) imaging system. The OCT subsystem consisted of a swept-source, Fourier-domain mode-locked (FDML) laser, with a very high A-scan rate (1.6 MHz), whose beam was raster scanned on the retina by two scanners—one resonant scanner and one galvanometer. The high sweep rate of the FDML permitted the SLO and OCT to utilize the same scanners for in vivo retinal imaging and, unlike existing multimodal systems, concurrently acquired SLO frames and OCT volumes ...

      Read Full Article
    2. Feature Of The Week 03/01/2019: Functional Retina lmaging using Adaptive Optics Swept-Source OCT at 1.6 MHz

      Feature Of The Week 03/01/2019: Functional Retina lmaging using Adaptive Optics Swept-Source OCT at 1.6 MHz

      Functional assessment of the retina is a critical part of both clinical ophthalmology and vision research. Several techniques exist for measuring retinal function, such as Visual acuity/contrast sensitivity tests, Psychophysics and ERG (Electroretinogram and multifocal Electroretinogram). However, these approaches have important limitations, poor spatial resolution, slightly invasive; long duration of tests. There is great excitement about emerging noninvasive approaches to measuring retinal function, both from clinical and basic scientific perspectives .With emerging approaches such as gene therapy, stem cell therapy, and transplantation, there is new hope for rescuing existing dysfunctional photoreceptors. A critical aspect of these therapeutic approaches is ...

      Read Full Article
    3. Functional retinal imaging using adaptive optics swept-source OCT at 1.6  MHz

      Functional retinal imaging using adaptive optics swept-source OCT at 1.6  MHz

      Objective optical assessment of photoreceptor function may permit earlier diagnosis of retinal disease than current methods such as perimetry, electrophysiology, and clinical imaging. In this work, we describe an adaptive optics (AO) optical coherence tomography (OCT) system designed to measure functional responses of single cones to visible stimuli. The OCT subsystem consisted of a raster-scanning Fourier-domain mode-locked laser that acquires A scans at 1.64 MHz with a center wavelength of 1063 nm and an AO system operating in closed-loop. Analysis of serial volumetric images revealed phase changes of cone photoreceptors consistent with outer segment elongation and proportional to stimulus ...

      Read Full Article
    4. Megahertz-rate optical coherence tomography angiography improves the contrast of the choriocapillaris and choroid in human retinal imaging

      Megahertz-rate optical coherence tomography angiography improves the contrast of the choriocapillaris and choroid in human retinal imaging

      Angiographic imaging of the human eye with optical coherence tomography (OCT) is becoming an increasingly important tool in the scientific investigation and clinical management of several blinding diseases, including age-related macular degeneration and diabetic retinopathy. We have observed that OCT angiography (OCTA) of the human choriocapillaris and choroid with a 1.64 MHz A-scan rate swept-source laser yields higher contrast images as compared to a slower rate system operating at 100 kHz. This result is unexpected because signal sensitivity is reduced when acquisition rates are increased, and the incident illumination power is kept constant. The contrast of angiography images generated ...

      Read Full Article
    5. Intraframe motion correction for raster-scanned adaptive optics images using strip-based cross-correlation lag biases

      Intraframe motion correction for raster-scanned adaptive optics images using strip-based cross-correlation lag biases

      In retinal raster imaging modalities, fixational eye movements manifest as image warp, where the relative positions of the beam and retina change during the acquisition of single frames. To remove warp artifacts, strip-based registration methods–in which fast-axis strips from target images are registered to a reference frame–have been applied in adaptive optics (AO) scanning light ophthalmoscopy (SLO) and optical coherence tomography (OCT). This approach has enabled object tracking and frame averaging, and methods have been described to automatically select reference frames with minimal motion. However, inconspicuous motion artifacts may persist in reference frames and propagate themselves throughout the ...

      Read Full Article
    6. Functional retinal imaging using adaptive optics swept-source OCT at 1.6MHz

      Functional retinal imaging using adaptive optics swept-source OCT at 1.6MHz

      bjective optical assessment of photoreceptor function may permit earlier diagnosis of retinal disease than current methods such as perimetry, electrophysiology, and clinical imaging. In this work, we describe an adaptive optics (AO) optical coherence tomography (OCT) system designed to measure functional responses of single cones to visible stimuli. The OCT subsystem consisted of a raster-scanning Fourier-domain mode-locked laser that acquires A-scans at 1.64MHz with a center wavelength of 1063nm, and an AO subsystem providing diffraction-limited imaging. Analysis of serial volumetric images revealed phase changes of cone photoreceptors consistent with outer segment elongation and proportional to stimulus intensity, as well ...

      Read Full Article
    7. The Properties of Outer Retinal Band Three Investigated With Adaptive-Optics Optical Coherence Tomography

      The Properties of Outer Retinal Band Three Investigated With Adaptive-Optics Optical Coherence Tomography

      Purpose : Optical coherence tomography's (OCT) third outer retinal band has been attributed to the zone of interdigitation between RPE cells and cone outer segments. The purpose of this paper is to investigate the structure of this band with adaptive optics (AO)-OCT. Methods : Using AO-OCT, images were obtained from two subjects. Axial structure was characterized by measuring band 3 thickness and separation between bands 2 and 3 in segmented cones. Lateral structure was characterized by correlation of band 3 with band 2 and comparison of their power spectra. Band thickness and separation were also measured in a clinical OCT ...

      Read Full Article
    1-8 of 8
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (8 articles) John S. Werner
    2. (8 articles) Robert J. Zawadzki
    3. (8 articles) Mehdi Azimipour
    4. (7 articles) Ravi S. Jonnal
    5. (5 articles) UC Davis
    6. (3 articles) UCSD
    7. (3 articles) Iwona Gorczynska
    8. (2 articles) Nicolaus Copernicus University
    9. (1 articles) Dalsa
    10. (1 articles) Thorlabs
  3. Popular Articles

  4. Picture Gallery

    The Properties of Outer Retinal Band Three Investigated With Adaptive-Optics Optical Coherence Tomography Functional retinal imaging using adaptive optics swept-source OCT at 1.6MHz Intraframe motion correction for raster-scanned adaptive optics images using strip-based cross-correlation lag biases Megahertz-rate optical coherence tomography angiography improves the contrast of the choriocapillaris and choroid in human retinal imaging Functional retinal imaging using adaptive optics swept-source OCT at 1.6  MHz Feature Of The Week 03/01/2019: Functional Retina lmaging using Adaptive Optics Swept-Source OCT at 1.6 MHz Coextensive synchronized SLO-OCT with adaptive optics for human retinal imaging Optoretinography: optical measurements of human cone and rod photoreceptor responses to light ORCA study: real-world versus reading centre assessment of disease activity of neovascular age-related macular degeneration (nAMD) Role of visual evoked potentials and optical coherence tomography in the screening for optic pathway gliomas in patients with neurofibromatosis type I An assessment of the quality of optical coherence tomography image acquisition Optical coherence tomography evaluation of vertebrobasilar artery stenosis: case series and literature review