1. Articles from Prafulla Kumar Maharana

    1-6 of 6
    1. Microscope Integrated Optical Coherence Tomography Guided Descemet Stripping Automated Endothelial Keratoplasty in Congenital Hereditary Endothelial Dystrophy

      Microscope Integrated Optical Coherence Tomography Guided Descemet Stripping Automated Endothelial Keratoplasty in Congenital Hereditary Endothelial Dystrophy

      Purpose: To describe the outcomes of descemet stripping automated endothelial keratoplasty (DSAEK) in congenital hereditary endothelial dystrophy (CHED) and to evaluate the role of microscope integrated optical coherence tomography (Mi-OCT) during the surgery. Design: Retrospective data analysis. Methods: A retrospective study from the medical records of all those patients who were diagnosed with CHED and underwent DSAEK at our centre from 2015 were evaluated. All patients underwent Mi-OCT-guided standard DSAEK procedure. Intra-operative difficulties, visual outcomes and graft survival were recorded. Results: A total of 48 eyes of 29 patients with a mean age of 9.87 ± 8.2 years and ...

      Read Full Article
    2. Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification

      Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification

      Purpose: To quantitatively analyze the dimensions of the gap between the intraocular lens (IOL) and the posterior capsule using microscope-integrated optical coherence tomography (MIOCT). Setting: Institutional. Design: Prospective, interventional. Methods: A total of 105 eyes of 105 consecutive patients planned for phacoemulsification with IOL implantation were enrolled. At the end of surgery, the gap between the IOL and the posterior capsule (IOL-PC gap) was measured using MIOCT (RESCAN). The same gap was reassessed at 1 week follow-up visit using the Visante-OCT system. The cases were sub-grouped based on the grade of cataract, IOL material, size and design and were analyzed ...

      Read Full Article
    3. Spontaneous anterior dislocation of lens in a case of ectopia lentis et pupillae: a rare entity treated by a novel technique of microscope integrated optical coherence tomography (MIOCT) guided intralenticular lens aspiration

      Spontaneous anterior dislocation of lens in a case of ectopia lentis et pupillae: a rare entity treated by a novel technique of microscope integrated optical coherence tomography (MIOCT) guided intralenticular lens aspiration

      A 7-year-old girl presented with watering and redness in the left eye for 2 months. Her parents reported poor vision in both eyes for 4 years. Visual acuity was finger counting at 1 m and finger counting close to face in the right and left eyes, respectively. Slit lamp examination of the right eye revealed corectopia, aphakia in the pupillary area, temporally subluxated clear crystalline lens, persistent pupillary membrane, irido-hyaloidal adhesion and poorly dilating pupil. Left eye revealed central corneal oedema with descemet scarring, anteriorly dislocated clear crystalline lens with lenticulo-corneal touch. Ultrasound examination of the left eye was normal ...

      Read Full Article
    4. Spectral Domain Anterior Segment Optical Coherence Tomography in Fungal Keratitis

      Spectral Domain Anterior Segment Optical Coherence Tomography in Fungal Keratitis

      Purpose: To evaluate the use of spectral domain anterior segment optical coherence tomography (SD-ASOCT) in fungal keratitis . Methods: Fifty eyes of 50 patients with fungal keratitis were recruited. Serial ASOCT was performed on days 0, 7, 14, 21, 28, 42, and 56. Corneal thickness (CT) in the infiltrate area, infiltrate thickness (IT), and infiltrate width were measured at each follow-up. The presence of any specific feature on ASOCT was evaluated. Results: Mean CT and IT at presentation were 650.5 ± 108 μm and 401.1 ± 91 μm, which reduced significantly at each follow-up [on days 7, 14, 28, and 42 ...

      Read Full Article
    5. Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation

      Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation

      Purpose: The aim of this study is to describe a modified surgical technique of continuous intraoperative optical coherence tomography (iOCT)-guided shield ulcer debridement with tuck-in multilayered Amniotic membrane transplantation (ML AMT) in vernal keratoconjunctivitis (VKC) with shield ulcer with plaque. Methods: Seven eyes of seven patients presenting with VKC with shield ulcer with plaque were enrolled in this prospective case series and planned for shield ulcer debridement with ML AMT. Debridement of the ulcer base with double-layered AMT was done under the continuous guidance of iOCT. The main outcome measure was the time for complete reepithelialization. Statistical analysis was ...

      Read Full Article
    6. Optical coherence tomography of the Kayser-Fleischer ring: an ancillary diagnostic tool for Wilsons disease in children

      Optical coherence tomography of the Kayser-Fleischer ring: an ancillary diagnostic tool for Wilsons disease in children

      This report presents anterior segment optical coherence tomography (AS-OCT) images of Kayser-Fleischer ring (KFR) in a child. The AS-OCT images highlight differential reflectivity of the KFR depending on amount of copper deposited in cornea, thus supporting the role of AS-OCT as a follow-up tool. Utility of AS-OCT for diagnosing and documenting the KFR in children otherwise uncooperative for detailed slit lamp examination is discussed.

      Read Full Article
    1-6 of 6
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (2 articles) Carl Zeiss Meditec
    2. (1 articles) Haag-Streit
    3. (1 articles) Leica
    4. (1 articles) Alcon
    5. (1 articles) Abbott
    6. (1 articles) Capital Medical University
  3. Popular Articles

  4. Picture Gallery

    Optical coherence tomography of the Kayser-Fleischer ring: an ancillary diagnostic tool for Wilsons disease in children Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation Spectral Domain Anterior Segment Optical Coherence Tomography in Fungal Keratitis Spontaneous anterior dislocation of lens in a case of ectopia lentis et pupillae: a rare entity treated by a novel technique of microscope integrated optical coherence tomography (MIOCT) guided intralenticular lens aspiration Quantitative Analysis of Gap Between the Intraocular Lens and Posterior Capsule Using Microscope-Integrated Optical Coherence Tomography in Eyes Undergoing Phacoemulsification Microscope Integrated Optical Coherence Tomography Guided Descemet Stripping Automated Endothelial Keratoplasty in Congenital Hereditary Endothelial Dystrophy Trojan-Horse Diameter-Reducible Nanotheranostics for Macroscopic/Microscopic Imaging-Monitored Chemo-Antiangiogenic Therapy Thickness of retinal pigment epithelium–Bruch’s membrane complex in adult Chinese using optical coherence tomography Interocular symmetry of optical coherence tomography parameters in healthy children and adolescents Fluorescein Leakage and Optical Coherence Tomography Angiography Features of Microaneurysms in Diabetic Retinopathy Cross-free in both lateral and axial directions Fourier-domain full-field optical coherence tomography Microperimetry, Humphrey field analyzer, and optical coherence tomography in detecting glaucoma: a comparative performance study