1. Articles from Siva Balasubramanian

    1-8 of 8
    1. Retinal Vascular Changes During Pregnancy Detected With Optical Coherence Tomography Angiograph

      Retinal Vascular Changes During Pregnancy Detected With Optical Coherence Tomography Angiograph

      Purpose : To evaluate retinal vascular status during pregnancy by using optical coherence tomography angiography (OCTA). Methods : Women in their third trimester of pregnancy and nonpregnant age-matched women were recruited for this prospective, case-control study. Subjects were imaged with OCTA. Main outcome measures were foveal avascular zone parameters, perfusion density (PD) percentage in the superficial retinal capillary plexus (SCP), PD percentage in the deep retinal capillary plexus (DCP), SCP vessel length density (VLD), DCP-VLD, and choriocapillaris (CC) flow voids (i.e., flow deficits in the CC). Results : Nineteen eyes of 10 pregnant subjects and 44 eyes of 27 nonpregnant control women ...

      Read Full Article
    2. Optical coherence tomography risk factors for development of late age related macular degeneration in the fellow eyes of patients enrolled in the HARBOR Study

      Optical coherence tomography risk factors for development of late age related macular degeneration in the fellow eyes of patients enrolled in the HARBOR Study

      Purpose To evaluate the relationship between optical coherence tomography (OCT) features and the progression to late age related macular degeneration (AMD) in the fellow eyes of patients enrolled in the 24-month HARBOR study (NCT00891735) for neovascular AMD. Design post hoc analysis of a phase 3 multicenter, prospective, randomized, double-masked, active treatment-controlled clinical trial. Participants Evaluable subjects (N=501) with macular neovascularization (MNV) secondary to neovascular AMD and early or intermediate AMD in the fellow eye. Methods Volume OCT scans from 501 fellow eyes of 501 patients with MNV were reviewed. Baseline OCT features that were assessed included intraretinal hypereflective foci ...

      Read Full Article
    3. Macular Microvascular Networks In Healthy Pediatric Subjects

      Macular Microvascular Networks In Healthy Pediatric Subjects

      Purpose: To report optical coherence tomography angiography ( OCTA ) values in healthy pediatric eyes and to identify factors that may modify these values. Methods: In this prospective observational cross-sectional study, macular OCTA images were acquired from healthy pediatric patients. Main outcome measures were 1) foveal avascular zone (FAZ) area at the level of the superficial retinal capillary plexus (SCP); 2) SCP and deep retinal capillary plexus (DCP) perfusion density (based on the area of vessels); 3) SCP and DCP vessel density (based on a map with vessels of 1-pixel width); and 4) CC perfusion density. Multiple regression analysis was performed to ...

      Read Full Article
    4. VISUAL FUNCTION AND OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY FEATURES IN CHILDREN BORN PRETERM

      VISUAL FUNCTION AND OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY FEATURES IN CHILDREN BORN PRETERM

      Purpose: Preterm children have an increased risk of impaired vision from retinopathy, strabismus, and high refractive error. The aim of this study was to investigate the relationship between foveal parameters generated by optical coherence tomography angiography and visual function in preterm children. Methods: Eighty eyes (32 eyes of former preterm infants and 48 age-matched full-term control eyes) were analyzed. Subjects underwent complete eye examinations including best-corrected visual acuity and retinal imaging with the Optovue XR Avanti optical coherence tomography angiography device. Foveal morphologic parameters including foveal depth, central foveal thickness, inner retinal area, and outer retinal area were measured on ...

      Read Full Article
    5. Multiple enface image averaging for enhanced optical coherence tomography angiography imaging

      Multiple enface image averaging for enhanced optical coherence tomography angiography imaging

      Purpose To investigate the effect of multiple enface image averaging on image quality of the optical coherence tomography angiography (OCTA). Methods Twenty‐one normal volunteers were enrolled in this study. For each subject, one eye was imaged with 3 × 3 mm scan protocol, and another eye was imaged with the 6 × 6 mm scan protocol centred on the fovea using the ZEISS Angioplex™ spectral‐domain OCTA device. Eyes were repeatedly imaged to obtain nine OCTA cube scan sets, and nine superficial capillary plexus (SCP) and deep capillary plexus (DCP) were individually averaged after registration. Results Eighteen eyes with a 3 ...

      Read Full Article
    6. Repeatability and Reproducibility of Superficial Macular Retinal Vessel Density Measurements Using Optical Coherence Tomography Angiography En Face Images

      Repeatability and Reproducibility of Superficial Macular Retinal Vessel Density Measurements Using Optical Coherence Tomography Angiography En Face Images

      Importance The repeatability and reproducibility of quantitative metrics from optical coherence tomographic angiography (OCTA) must be assessed before these data can be confidently interpreted in clinical research and practice. Objective To evaluate the repeatability and reproducibility of OCTA-derived retinal vascular quantitative metrics. Design, Setting and Participants In this cross-sectional study, 21 healthy volunteers (42 eyes) and 22 patients with retinal disease (22 eyes), including 14 with age-related macular degeneration, 3 with epiretinal membrane, 2 with diabetic retinopathy, 2 with myopic macular degeneration, and 1 with retinal vein occlusion, were enrolled. Participants were recruited from September 1 through November 31, 2016 ...

      Read Full Article
    7. Impact of Multiple En Face Image Averaging on Quantitative Assessment from Optical Coherence Tomography Angiography Images

      Impact of Multiple En Face Image Averaging on Quantitative Assessment from Optical Coherence Tomography Angiography Images

      Purpose To investigate the impact of multiple en face image averaging on quantitative measurements of the retinal microvasculature using optical coherence tomography angiography (OCTA). Design Prospective, observational, cross-sectional case series. Participants Twenty-one healthy individuals with normal eyes. Methods Macular OCTA images were acquired from all participants using the Zeiss Cirrus 5000 with Angioplex OCTA software (Carl Zeiss Meditec, Dublin, CA). Nine OCTA cube scans per eye were obtained and 9 superficial retinal layer (SRL) and deep retinal layer (DRL) en face OCTA image slabs were averaged individually after registration. Quantitative parameters from the retinal microvasculature were measured on binarized and ...

      Read Full Article
    8. Variability of Retinal Thickness Measurements in Tilted or Stretched Optical Coherence Tomography Images

      Variability of Retinal Thickness Measurements in Tilted or Stretched Optical Coherence Tomography Images

      Purpose : To investigate the level of inaccuracy of retinal thickness measurements in tilted and axially stretched optical coherence tomography (OCT) images. Methods : A consecutive series of 50 eyes of 50 patients with age-related macular degeneration were included in this study, and Cirrus HD-OCT images through the foveal center were used for the analysis. The foveal thickness was measured in three ways: (1) parallel to the orientation of the A-scan (Tx), (2) perpendicular to the retinal pigment epithelium (RPE) surface in the instrument-displayed aspect ratio image (Ty), and (3) thickness measured perpendicular to the RPE surface in a native aspect ratio ...

      Read Full Article
    1-8 of 8
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (8 articles) Srinivas R. Sadda
    2. (6 articles) UCLA
    3. (1 articles) UCSF
    4. (1 articles) University of Southern California
    5. (1 articles) Mary K. Durbin
    6. (1 articles) Optovue
    7. (1 articles) Carl Zeiss Meditec
    8. (1 articles) Zeiss Cirrus HD-OCT
    9. (1 articles) Massachusetts Eye and Ear Infirmary
    10. (1 articles) Harvard University
    11. (1 articles) Case Western Reserve University
    12. (1 articles) David L. Wilson
    13. (1 articles) Optovue
    14. (1 articles) Precitec Optronik
    15. (1 articles) Carl Zeiss Meditec
    16. (1 articles) St. Jude Medical
    17. (1 articles) Topcon Medical Systems
  3. Popular Articles

  4. Picture Gallery

    Variability of Retinal Thickness Measurements in Tilted or Stretched Optical Coherence Tomography Images Impact of Multiple En Face Image Averaging on Quantitative Assessment from Optical Coherence Tomography Angiography Images Repeatability and Reproducibility of Superficial Macular Retinal Vessel Density Measurements Using Optical Coherence Tomography Angiography En Face Images Multiple enface image averaging for enhanced optical coherence tomography angiography imaging VISUAL FUNCTION AND OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY FEATURES IN CHILDREN BORN PRETERM Macular Microvascular Networks In Healthy Pediatric Subjects Optical coherence tomography risk factors for development of late age related macular degeneration in the fellow eyes of patients enrolled in the HARBOR Study Retinal Vascular Changes During Pregnancy Detected With Optical Coherence Tomography Angiograph Optical Coherence Tomography Angiography in Myopic Patients Quantification of retinal microvasculature and neurodegeneration changes in branch retinal vein occlusion after resolution of cystoid macular edema on optical coherence tomography angiography Machining head for a laser machining device Quantitative Comparison Of Microvascular Metrics On Three Optical Coherence Tomography Angiography Devices In Chorioretinal Disease