1. Articles from Taku Asano

    1-7 of 7
    1. Optical coherence tomography substudy of a prospective multicentre randomised post-market trial to assess the safety and effectiveness of the Firehawk cobalt-chromium coronary stent (rapamycin target-eluting) system for the treatment of atherosclerotic le

      Optical coherence tomography substudy of a prospective multicentre randomised post-market trial to assess the safety and effectiveness of the Firehawk cobalt-chromium coronary stent (rapamycin target-eluting) system for the treatment of atherosclerotic le

      Aims: Durable polymer drug-eluting stents (DP-DES) may contribute to persistent inflammation, delayed endothelial healing and subsequent late DES thrombosis. The aim of this optical coherence tomography (OCT) substudy was to compare healing and neointimal coverage of a novel bioabsorbable polymer sirolimus-eluting stent (Firehawk ® ) (BP-DES) versus the DP-DES (XIENCE) at 90 days in an all-comers patient population. Methods and results: The TARGET All Comers study is a prospective multicentre randomised post-market trial of 1,656 patients randomised 1:1 to Firehawk or XIENCE at 21 centres in 10 European countries. The TARGET OCT substudy enrolled 36 consecutive patients with 52 lesions ...

      Read Full Article
    2. Optical Coherence Tomography Substudy of A Prospective Multicenter Randomized Post-Market Trial to Assess the Safety and Effectiveness of the Firehawk™ Rapamycin Target Eluting Cobalt Chromium Coronary Stent System for the Treatment of Atherosclerotic Les

      Optical Coherence Tomography Substudy of A Prospective Multicenter Randomized Post-Market Trial to Assess the Safety and Effectiveness of the Firehawk™ Rapamycin Target Eluting Cobalt Chromium Coronary Stent System for the Treatment of Atherosclerotic Les

      Aims: Durable polymer drug-eluting stents (DP DES) may contribute to persistent inflammation, delayed endothelial healing and subsequent late DES thrombosis. The aim of this Optical Coherence Tomography (OCT) sub-study was to compare healing and neointimal coverage of a novel bioabsorbable polymer sirolimus-eluting stent (FIREHAWK®) (BP DES) versus the DP DES (XIENCE) at 90 days in an all comers patient population. Methods and results: The TARGET All Comers study is a prospective multicenter randomised post-market trial of 1656 patients randomised 1:1 to FIREHAWK or XIENCE at 21 centers in 10 European countries. The TARGET OCT sub-study enrolled 36 consecutive patients ...

      Read Full Article
    3. Quality difference of neointima following the implantation of bioresorbable scaffold and metallic stent in patients with ST elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coheren

      Quality difference of neointima following the implantation of bioresorbable scaffold and metallic stent in patients with ST elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coheren

      Aims: We aimed to assess possible difference of the neointimal quality after everolimus-eluting bioresorbable scaffold (BVS) implantation in comparison with cobalt chromium everolimus-eluting scaffold (CoCr-EES) by optical frequency domain imaging (OFDI). Methods and results: This study is a post-hoc analysis of TROFI II trial assessing neointimal quality 6-month after the implantation of BVS(N=82) and CoCr-EES(N=87) in STEMI patients. Neointimal light property analysis by OFDI full-automatically computed light attenuation, backscatter and light intensity for superficial and deep neointima. High light attenuation/backscatter and high light intensity are reportedly associated with lipidic change and tissue maturation, respectively. Superficial ...

      Read Full Article
    4. Coronary calcification as a mechanism of plaque/media shrinkage in vessels treated with bioresorbable vascular scaffold: A multimodality intracoronary imaging study

      Coronary calcification as a mechanism of plaque/media shrinkage in vessels treated with bioresorbable vascular scaffold: A multimodality intracoronary imaging study

      Background and aims Whether coronary calcification is correlated with plaque/media shrinkage (PS) remains unclear. The aim of this study was to assess the relationship between the calcification process and PS, combining serial optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in vessels treated with bioresorbable vascular scaffolds (BVS). Methods In 15 patients (16 vessels), OCT and IVUS images were matched using anatomic landmarks at post-procedure and five years. PS was defined as relative decrease in plaque/media area >5%. The association between the calcification process and PS was investigated. Mixed effects model was used to assess correlations and changes ...

      Read Full Article
    5. Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography

      Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography

      Background— The long-term fate of Absorb bioresorbable vascular scaffold (Abbott Vascular, Santa Clara, CA) struts jailing side branch ostia has not been clarified. We therefore evaluate serially (post-procedure and at 6 months, 1, 2, 3, and 5 years) the appearance and fate of jailed Absorb bioresorbable vascular scaffold struts. Methods and Results— We performed 3-dimensional optical coherence tomographic analysis of the ABSORB Cohort B trial (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) up to 5 years using a novel, validated cut-plane analysis method. We ...

      Read Full Article
    6. Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus eluting bioresorbable polylactide scaffold in comparison with the cobalt chromium metallic stent?

      Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus eluting bioresorbable polylactide scaffold in comparison with the cobalt chromium metallic stent?

      Aims: Immediately after stent/scaffold implantation, quantitative coronary angiography (QCA) with respect to optical coherence tomography (OCT) more severely underestimates the lumen diameter (LD) in Absorb than in XIENCE. This OCT-QCA discrepancy has not been evaluated at long-term follow-up. The present study aimed to assess the accuracy of QCA with reference to OCT in Absorb as compared to XIENCE.

       

       

      Read Full Article
    7. Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography

      Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography

      To establish the accuracy of coronary computed tomography angiography (CTA) for in-scaffold quantitative evaluation with optical coherence tomography (OCT) as a reference. The translucent backbone of the bioresorbable scaffold allow us to evaluate non-invasively the coronary lumen with coronary CTA. In the ABSORB first-in-man studies, coronary CTA was shown to be feasible for quantitative luminal assessment. Nevertheless, a comparison with an intravascular modality with higher resolution has never been performed. In the ABSORB Cohort B trial, 101 patient with non-complex lesions were treated with the fully biodegradable vascular scaffold. For this analysis, all patients who underwent coronary CTA at 18 ...

      Read Full Article
    1-7 of 7
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (7 articles) Erasmus University
    2. (7 articles) Patrick W. Serruys
    3. (6 articles) Yoshinobu Onuma
    4. (2 articles) Academic Medical Center at the University of Amsterdam
    5. (2 articles) National University of Ireland, Galway
    6. (2 articles) Chinese Academy of Sciences
    7. (2 articles) Leiden University
    8. (2 articles) Stephan Windecker
    9. (2 articles) Jouke Dijkstra
    10. (1 articles) Nico Bruining
  3. Popular Articles

  4. Picture Gallery

    Accuracy of coronary computed tomography angiography for bioresorbable scaffold luminal investigation: a comparison with optical coherence tomography Is quantitative coronary angiography reliable in assessing the late lumen loss of the everolimus eluting bioresorbable polylactide scaffold in comparison with the cobalt chromium metallic stent? Serial 5-Year Evaluation of Side Branches Jailed by Bioresorbable Vascular Scaffolds Using 3-Dimensional Optical Coherence Tomography Coronary calcification as a mechanism of plaque/media shrinkage in vessels treated with bioresorbable vascular scaffold: A multimodality intracoronary imaging study Quality difference of neointima following the implantation of bioresorbable scaffold and metallic stent in patients with ST elevation myocardial infarction: quantitative assessments by light intensity, light attenuation, and backscatter on optical coheren Optical Coherence Tomography Substudy of A Prospective Multicenter Randomized Post-Market Trial to Assess the Safety and Effectiveness of the Firehawk™ Rapamycin Target Eluting Cobalt Chromium Coronary Stent System for the Treatment of Atherosclerotic Les Optical coherence tomography substudy of a prospective multicentre randomised post-market trial to assess the safety and effectiveness of the Firehawk cobalt-chromium coronary stent (rapamycin target-eluting) system for the treatment of atherosclerotic le Changes in the OCT angiographic appearance of type 1 and type 2 CNV in exudative AMD during anti-VEGF treatment Optical coherence angiography for pre-treatment assessment and treatment monitoring following photodynamic therapy: a basal cell carcinoma patient study Computational aberration correction in spatiotemporal optical coherence (STOC) imaging A rare entity: Sympathetic ophthalmia presumably after blunt trauma to the phthisical eye and optical coherence tomography angiography metrics to monitor response to treatment Mechanism of fluid leak in non-traumatic corneal perforations: an anterior segment optical coherence tomography study