1. Articles from Srilakshmi Dasari

    1-9 of 9
    1. Referenced scans improve the repeatability of optical coherence tomography angiography measurements in normal and glaucoma eyes

      Referenced scans improve the repeatability of optical coherence tomography angiography measurements in normal and glaucoma eyes

      Aim To compare the repeatability of peripapillary perfusion density and flux index measurements on referenced and non-referenced optical microangiography (OMAG) scans in normal, glaucoma suspect and glaucoma eyes. Methods In a cross-sectional study, 48 eyes (33 subjects) underwent three repeat, non-referenced peripapillary OMAG scans in the same session and 43 eyes (25 subjects) underwent three referenced peripapillary OMAG scans. In the referenced scan group, repeat scans (second and the third scan) were acquired exactly on the baseline (first) scan using the ‘track to prior scan’ option on the device. Repeatability estimates of the mean and four-sector (temporal, superior, nasal and ...

      Read Full Article
    2. A 3D Deep Learning System for Detecting Referable Glaucoma Using Full OCT Macular Cube Scans

      A 3D Deep Learning System for Detecting Referable Glaucoma Using Full OCT Macular Cube Scans

      Purpose : The purpose of this study was to develop a 3D deep learning system from spectral domain optical coherence tomography (SD-OCT) macular cubes to differentiate between referable and nonreferable cases for glaucoma applied to real-world datasets to understand how this would affect the performance. Methods : There were 2805 Cirrus optical coherence tomography (OCT) macula volumes (Macula protocol 512 × 128) of 1095 eyes from 586 patients at a single site that were used to train a fully 3D convolutional neural network (CNN). Referable glaucoma included true glaucoma, pre-perimetric glaucoma, and high-risk suspects, based on qualitative fundus photographs, visual fields, OCT reports ...

      Read Full Article
    3. Repeatability and comparability of peripapillary vessel density measurements of high-density and non-high-density optical coherence tomography angiography scans in normal and glaucoma eyes

      Repeatability and comparability of peripapillary vessel density measurements of high-density and non-high-density optical coherence tomography angiography scans in normal and glaucoma eyes

      Aims To compare the peripapillary vessel density (VD) measurements of high-density (HD) and non-HD optical coherence tomography angiography (OCTA) scans in normal and glaucoma eyes, and to evaluate the intrasession repeatability of VD measurements of HD scans. Methods In a cross-sectional study, 46 normal (33 subjects) and 89 glaucoma (64 patients) eyes underwent 3 HD and 1 non-HD optic nerve head OCTA scans in the same session. Agreement in VD measurements between HD and non-HD scans was assessed using Bland and Altman analysis. Repeatability of the VD measurements of HD scans was assessed using within-subject coefficient of repeatability (CRw) and ...

      Read Full Article
    4. Diagnostic Abilities of the Optical Microangiography Parameters of the 3×3 mm and 6×6 mm Macular Scans in Glaucoma

      Diagnostic Abilities of the Optical Microangiography Parameters of the 3×3 mm and 6×6 mm Macular Scans in Glaucoma

      Purpose: To evaluate the diagnostic abilities of macular vessel length and perfusion densities measured with optical microangiography (OMAG) over a 3×3 mm and a 6×6 mm region, and to compare these with macular ganglion cell-inner plexiform layer (GCIPL) thickness in eyes with primary open-angle glaucoma (POAG). Methods: In a cross-sectional study, 96 eyes of 57 control subjects and 88 eyes of 57 POAG patients underwent macular imaging with optical coherence tomography. Area under receiver operating characteristic curves (AUC) and sensitivities at 90% specificity of OMAG and GCIPL parameters were evaluated. Results: Most OMAG parameters of the 3×3 ...

      Read Full Article
    5. Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes With Primary Open-Angle Glaucoma and Disc Hemorrhage

      Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes With Primary Open-Angle Glaucoma and Disc Hemorrhage

      Purpose: To compare the vessel density measurements of optic nerve head, peripapillary and macular regions in severity-matched primary open-angle glaucoma (POAG) eyes with and without disc hemorrhage (DH) using optical coherence tomography (OCT) angiography, and to compare their diagnostic abilities with that of the rim area, retinal nerve fiber layer and the ganglion cell complex thickness measurements on OCT. Methods: In a cross-sectional study, 66 eyes of 46 control subjects, 34 eyes of 33 POAG patients with DH (median mean deviation=−3.7 dB) and 63 eyes of 43 POAG patients without DH (median mean deviation=−3.8 dB) underwent ...

      Read Full Article
    6. A comparison of the diagnostic ability of vessel density and structural measurements of optical coherence tomography in primary open angle glaucoma

      A comparison of the diagnostic ability of vessel density and structural measurements of optical coherence tomography in primary open angle glaucoma

      Purpose To compare the diagnostic abilities of vessel density measurements of the optic nerve head (ONH), peripapillary and macular regions on optical coherence tomography (OCT) angiography in eyes with primary open angle glaucoma (POAG) with that of the ONH rim area, peripapillary retinal nerve fiber layer (RNFL) thickness and the macular ganglion cell complex (GCC) thickness measurements. Methods In a cross sectional study, 78 eyes of 50 control subjects and 117 eyes of 67 POAG patients underwent vessel density and structural measurements with spectral domain OCT. POAG was diagnosed based on the masked evaluation of optic disc stereo photographs. Area ...

      Read Full Article
    7. Vessel density and structural measurements of optical coherence tomography in primary angle closure and primary angle closure glaucoma

      Vessel density and structural measurements of optical coherence tomography in primary angle closure and primary angle closure glaucoma

      Purpose To evaluate the vessel density measurements of the optic nerve head (ONH), peripapillary and macular regions on optical coherence tomography (OCT) angiography in eyes with primary angle closure (PAC) and primary angle closure glaucoma (PACG), and to compare their diagnostic abilities with the ONH rim area, peripapillary retinal nerve fiber layer (RNFL) thickness and the macular ganglion cell complex (GCC) thickness measurements on OCT in PACG. Design Cross-sectional study Methods Seventy-seven eyes of 50 control subjects, 65 eyes of 45 patients with PACG, and 31 eyes of 22 PAC patients with a history of high IOP, underwent imaging with ...

      Read Full Article
    8. Predicting the intereye asymmetry in functional and structural damage in glaucoma using automated pupillography

      Predicting the intereye asymmetry in functional and structural damage in glaucoma using automated pupillography

      Purpose To predict the intereye asymmetry in functional (mean deviation, MD on visual field, VF) and structural (retinal nerve fibre layer, RNFL and ganglion cell complex, GCC thickness on spectral domain optical coherence tomography, SDOCT) measurements in glaucoma using the automated pupillography parameters. Methods Fifty-nine subjects with a diagnosis of either glaucoma or glaucoma suspect underwent automated pupillography along with VF and SDOCT examinations. Association between pupillography and the absolute intereye difference in MD, RNFL and GCC measurements was evaluated using regression analysis after accounting for the multicollinearity. Results Univariate regression analysis showed statistically significant associations (p < 0.05) between ...

      Read Full Article
    9. Regional comparisons of optical coherence tomography angiography vessel density in primary open angle glaucoma

      Regional comparisons of optical coherence tomography angiography vessel density in primary open angle glaucoma

      Purpose To compare the diagnostic abilities of the vessel densities in optic nerve head (ONH), peripapillary and macular regions measured using optical coherence tomography angiography (OCTA) in eyes with primary open angle glaucoma (POAG), and to evaluate the effect of glaucoma severity (based on the mean deviation, MD), optic disc size and pre-treatment intraocular pressure (IOP). Design Cross-sectional study Methods Seventy-eight eyes of 53 control subjects and 64 eyes of 39 POAG patients underwent OCTA imaging. Area under receiver operating characteristic (ROC) curves (AUC) and sensitivities at fixed specificities of vessel densities in ONH, peripapillary and macular regions were analyzed ...

      Read Full Article
    1-9 of 9
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (8 articles) Harsha L. Rao
    2. (7 articles) Robert N. Weinreb
    3. (6 articles) UCSD
    4. (3 articles) University of Washington
    5. (2 articles) Ruikang K. Wang
    6. (1 articles) Rohit Shetty
    7. (1 articles) Optovue
    8. (1 articles) Topcon Medical Systems
    9. (1 articles) Carl Zeiss Meditec
    10. (1 articles) Voxeleron
    11. (1 articles) Heidelberg Engineering
    12. (1 articles) Bausch & Lomb
    13. (1 articles) Zhejiang University
    14. (1 articles) Cleveland Clinic
    15. (1 articles) UCSD
    16. (1 articles) Sunil K. Srivastava
    17. (1 articles) Justis P. Ehlers
    18. (1 articles) William R. Freeman
    19. (1 articles) Peng Li
    20. (1 articles) Optovue
  3. Popular Articles

  4. Picture Gallery

    Regional comparisons of optical coherence tomography angiography vessel density in primary open angle glaucoma Predicting the intereye asymmetry in functional and structural damage in glaucoma using automated pupillography Vessel density and structural measurements of optical coherence tomography in primary angle closure and primary angle closure glaucoma A comparison of the diagnostic ability of vessel density and structural measurements of optical coherence tomography in primary open angle glaucoma Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes With Primary Open-Angle Glaucoma and Disc Hemorrhage Diagnostic Abilities of the Optical Microangiography Parameters of the 3×3 mm and 6×6 mm Macular Scans in Glaucoma Repeatability and comparability of peripapillary vessel density measurements of high-density and non-high-density optical coherence tomography angiography scans in normal and glaucoma eyes A 3D Deep Learning System for Detecting Referable Glaucoma Using Full OCT Macular Cube Scans Referenced scans improve the repeatability of optical coherence tomography angiography measurements in normal and glaucoma eyes Impact of cardiometabolic factors on retinal vasculature: A 3x3, 6x6 and 8x8-mm optical coherence tomography angiography study Quantitative research on the interaction between cerebral edema and peripheral cerebral blood perfusion using swept-source optical coherence tomography Optical coherence tomography angiography measures blood pulsatile waveforms at variable tissue depths