1. Articles from Dhanaraj A. S. Rao

    1-8 of 8
    1. Optical Coherence Tomography Angiography and Visual Field Progression in Primary Angle Closure Glaucoma

      Optical Coherence Tomography Angiography and Visual Field Progression in Primary Angle Closure Glaucoma

      Precis: Lower whole enface disc (coefficient: 0.02, P =0.03) and macular vessel densities (coefficient: 0.04, P =0.02) on OCT angiography were significantly associated with faster rate of mean deviation decline. Purpose: To evaluate the association between optical coherence tomography angiography (OCTA) features and prior visual field (VF) progression in primary angle closure glaucoma (PACG). Methods: In a cross-sectional study, 46 eyes of 31 PACG patients with 5 reliable VF examinations performed over ≥3 years of follow-up underwent OCTA imaging. Effect of clinical (age, gender, number of anti-glaucoma medications, mean and SD of intraocular pressure during follow-up ...

      Read Full Article
    2. Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes With Primary Open-Angle Glaucoma and Disc Hemorrhage

      Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes With Primary Open-Angle Glaucoma and Disc Hemorrhage

      Purpose: To compare the vessel density measurements of optic nerve head, peripapillary and macular regions in severity-matched primary open-angle glaucoma (POAG) eyes with and without disc hemorrhage (DH) using optical coherence tomography (OCT) angiography, and to compare their diagnostic abilities with that of the rim area, retinal nerve fiber layer and the ganglion cell complex thickness measurements on OCT. Methods: In a cross-sectional study, 66 eyes of 46 control subjects, 34 eyes of 33 POAG patients with DH (median mean deviation=−3.7 dB) and 63 eyes of 43 POAG patients without DH (median mean deviation=−3.8 dB) underwent ...

      Read Full Article
    3. Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes with Primary Open Angle Glaucoma and Disc Hemorrhage

      Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes with Primary Open Angle Glaucoma and Disc Hemorrhage

      Purpose: To compare the vessel density measurements of optic nerve head (ONH), peripapillary and macular regions in severity-matched primary open angle glaucoma (POAG) eyes with and without disc hemorrhage (DH) using optical coherence tomography (OCT) angiography (OCTA), and to compare their diagnostic abilities with that of the rim area, retinal nerve fiber layer and the ganglion cell complex thickness measurements on OCT. Methods: In a cross-sectional study, 66 eyes of 46 control subjects, 34 eyes of 33 POAG patients with DH (median mean deviation, MD: -3.7 dB) and 63 eyes of 43 POAG patients without DH (median MD: -3 ...

      Read Full Article
    4. A comparison of the diagnostic ability of vessel density and structural measurements of optical coherence tomography in primary open angle glaucoma

      A comparison of the diagnostic ability of vessel density and structural measurements of optical coherence tomography in primary open angle glaucoma

      Purpose To compare the diagnostic abilities of vessel density measurements of the optic nerve head (ONH), peripapillary and macular regions on optical coherence tomography (OCT) angiography in eyes with primary open angle glaucoma (POAG) with that of the ONH rim area, peripapillary retinal nerve fiber layer (RNFL) thickness and the macular ganglion cell complex (GCC) thickness measurements. Methods In a cross sectional study, 78 eyes of 50 control subjects and 117 eyes of 67 POAG patients underwent vessel density and structural measurements with spectral domain OCT. POAG was diagnosed based on the masked evaluation of optic disc stereo photographs. Area ...

      Read Full Article
    5. Vessel density and structural measurements of optical coherence tomography in primary angle closure and primary angle closure glaucoma

      Vessel density and structural measurements of optical coherence tomography in primary angle closure and primary angle closure glaucoma

      Purpose To evaluate the vessel density measurements of the optic nerve head (ONH), peripapillary and macular regions on optical coherence tomography (OCT) angiography in eyes with primary angle closure (PAC) and primary angle closure glaucoma (PACG), and to compare their diagnostic abilities with the ONH rim area, peripapillary retinal nerve fiber layer (RNFL) thickness and the macular ganglion cell complex (GCC) thickness measurements on OCT in PACG. Design Cross-sectional study Methods Seventy-seven eyes of 50 control subjects, 65 eyes of 45 patients with PACG, and 31 eyes of 22 PAC patients with a history of high IOP, underwent imaging with ...

      Read Full Article
    6. Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma

      Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma

      Aims To evaluate the diagnostic ability of peripapillary vessel density measurements on optical coherence tomography angiography (OCTA) in primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG), and to compare these with peripapillary retinal nerve fibre layer (RNFL) thickness measurements. Methods In a cross-sectional study, 48 eyes of 33 healthy control subjects, 63 eyes of 39 patients with POAG and 49 eyes of 32 patients with PACG underwent OCTA (RTVue-XR, Optovue, Fremont, California, USA) and RNFL imaging with spectral domain OCT. Diagnostic abilities of vessel density and RNFL parameters were evaluated using area under receiver operating characteristic curves (AUC) and ...

      Read Full Article
    7. Predicting the intereye asymmetry in functional and structural damage in glaucoma using automated pupillography

      Predicting the intereye asymmetry in functional and structural damage in glaucoma using automated pupillography

      Purpose To predict the intereye asymmetry in functional (mean deviation, MD on visual field, VF) and structural (retinal nerve fibre layer, RNFL and ganglion cell complex, GCC thickness on spectral domain optical coherence tomography, SDOCT) measurements in glaucoma using the automated pupillography parameters. Methods Fifty-nine subjects with a diagnosis of either glaucoma or glaucoma suspect underwent automated pupillography along with VF and SDOCT examinations. Association between pupillography and the absolute intereye difference in MD, RNFL and GCC measurements was evaluated using regression analysis after accounting for the multicollinearity. Results Univariate regression analysis showed statistically significant associations (p < 0.05) between ...

      Read Full Article
    8. Regional comparisons of optical coherence tomography angiography vessel density in primary open angle glaucoma

      Regional comparisons of optical coherence tomography angiography vessel density in primary open angle glaucoma

      Purpose To compare the diagnostic abilities of the vessel densities in optic nerve head (ONH), peripapillary and macular regions measured using optical coherence tomography angiography (OCTA) in eyes with primary open angle glaucoma (POAG), and to evaluate the effect of glaucoma severity (based on the mean deviation, MD), optic disc size and pre-treatment intraocular pressure (IOP). Design Cross-sectional study Methods Seventy-eight eyes of 53 control subjects and 64 eyes of 39 POAG patients underwent OCTA imaging. Area under receiver operating characteristic (ROC) curves (AUC) and sensitivities at fixed specificities of vessel densities in ONH, peripapillary and macular regions were analyzed ...

      Read Full Article
    1-8 of 8
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (8 articles) Harsha L. Rao
    2. (7 articles) Robert N. Weinreb
    3. (6 articles) UCSD
    4. (2 articles) Rohit Shetty
    5. (2 articles) Optovue
    6. (1 articles) Academic Hospital Maastricht
    7. (1 articles) Topcon Medical Systems
    8. (1 articles) Carl Zeiss Meditec
    9. (1 articles) Heidelberg Engineering
    10. (1 articles) Bausch & Lomb
    11. (1 articles) University of Copenhagen
    12. (1 articles) Center for Ophthalmic Optics and Lasers
    13. (1 articles) FDA
    14. (1 articles) Oregon Health & Science University
    15. (1 articles) SUNY at Stony Brook
    16. (1 articles) University College London
    17. (1 articles) David Huang
    18. (1 articles) Axel Petzold
    19. (1 articles) Perimeter Medical Imaging
    20. (1 articles) Carl Zeiss Meditec
  3. Popular Articles

  4. Picture Gallery

    Regional comparisons of optical coherence tomography angiography vessel density in primary open angle glaucoma Predicting the intereye asymmetry in functional and structural damage in glaucoma using automated pupillography Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma Vessel density and structural measurements of optical coherence tomography in primary angle closure and primary angle closure glaucoma A comparison of the diagnostic ability of vessel density and structural measurements of optical coherence tomography in primary open angle glaucoma Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes with Primary Open Angle Glaucoma and Disc Hemorrhage Optical Coherence Tomography Angiography Vessel Density Measurements in Eyes With Primary Open-Angle Glaucoma and Disc Hemorrhage Optical Coherence Tomography Angiography and Visual Field Progression in Primary Angle Closure Glaucoma EARLY SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY BIOMARKERS TO CONFIRM FELLOW EYE CHANGES IN ASYMMETRIC TYPE-2 MACULAR TELANGIECTASIA Relative Postpartum Retinal Vasoconstriction Detected With Optical Coherence Tomography Angiography 1.1 μm waveband tunable laser using emission-wavelength-controlled InAs quantum dots for swept-source optical coherence tomography applications Retinal nerve fibre layer and peripapillary vascular density by optical coherence tomography angiography in schizophrenia