1. Articles from Eric Shieh

    1-6 of 6
    1. Diagnostic Capability of 3D Peripapillary Retinal Volume for Glaucoma Using Optical Coherence Tomography Customized Software

      Diagnostic Capability of 3D Peripapillary Retinal Volume for Glaucoma Using Optical Coherence Tomography Customized Software

      Précis: The diagnostic capability of peripapillary retinal volume is similar to peripapillary retinal nerve fiber layer thickness for diagnosing glaucoma, but with fewer artifacts. Purpose: To compare the diagnostic capability of three-dimensional (3D) peripapillary retinal volume (RV) versus two-dimensional (2D) peripapillary retinal nerve fiber layer (RNFL) thickness for open-angle glaucoma . Patients and Methods: A retrospective cross-sectional analysis was conducted. A total of 180 subjects [113 open-angle glaucomas (OAG), 67 normal participants] had spectral domain optical coherence tomography (OCT) volume scans and RNFL thickness measurements. Peripapillary RV values were calculated using a custom-designed program with 4 circumpapillary annuli (CA): CA1 ...

      Read Full Article
    2. Effects of Age, Race, and Ethnicity on the Optic Nerve and Peripapillary Region Using Spectral-Domain OCT 3D Volume Scans

      Effects of Age, Race, and Ethnicity on the Optic Nerve and Peripapillary Region Using Spectral-Domain OCT 3D Volume Scans

      Purpose : To evaluate the effects of age, race, and ethnicity on the optic nerve and peripapillary retina using spectral-domain optical coherence tomography (SD-OCT) three-dimensional (3D) volume scans in normal subjects. Methods : This is a cross-sectional study performed at a single institution in Boston. All patients received retinal nerve fiber layer (RNFL) scans and an optic nerve 3D volume scan. The SD-OCT software calculated peripapillary RNFL thickness, retinal thickness (RT), and retinal volume (RV). Custom-designed software calculated neuroretinal rim minimum distance band (MDB) thickness and area. Results : There were 272 normal subjects, including 175 whites, 40 blacks, 40 Asians, and 17 ...

      Read Full Article
    3. Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans

      Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans

      Purpose : To compare the diagnostic capability of three-dimensional (3D) macular parameters against traditional two-dimensional (2D) retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography. To determine if manual correction and interpolation of B-scans improve the ability of 3D macular parameters to diagnose glaucoma. Methods : A total of 101 open angle glaucoma patients (29 with early glaucoma) and 57 healthy subjects had peripapillary 2D RNFL thickness and 3D macular volume scans. Four parameters were calculated for six different-sized annuli: total macular thickness (M-thickness), total macular volume (M-volume), ganglion cell complex (GCC) thickness, and GCC volume of the innermost ...

      Read Full Article
    4. Diagnostic Capability of Peripapillary 3D Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans

      Diagnostic Capability of Peripapillary 3D Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans

      Purpose To determine the diagnostic capability of peripapillary 3-dimensional (3D) retinal nerve fiber layer (RNFL) volume measurements from spectral domain optical coherence tomography (OCT) volume scans for open angle glaucoma (OAG). Design Assessment of diagnostic accuracy. Methods Setting: Academic clinical setting. Study population : 180 patients (113 OAG and 67 normal subjects). Observation procedures : One eye per subject was included. Peripapillary 3D RNFL volumes were calculated for global, quadrant, and sector regions, using four different sized annuli. Peripapillary 2D RNFL thickness circle scans were also obtained. Main outcome measures : Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive ...

      Read Full Article
    5. Comprehensive Three-Dimensional Analysis of the Neuroretinal Rim in Glaucoma Using High-Density Spectral-Domain Optical Coherence Tomography Volume Scans

      Comprehensive Three-Dimensional Analysis of the Neuroretinal Rim in Glaucoma Using High-Density Spectral-Domain Optical Coherence Tomography Volume Scans

      Purpose : To describe spectral-domain optical coherence tomography (OCT) methods for quantifying neuroretinal rim tissue in glaucoma and to compare these methods to the traditional retinal nerve fiber layer thickness diagnostic parameter. Methods : Neuroretinal rim parameters derived from three-dimensional (3D) volume scans were compared with the two-dimensional (2D) Spectralis retinal nerve fiber layer (RNFL) thickness scans for diagnostic capability. This study analyzed one eye per patient of 104 glaucoma patients and 58 healthy subjects. The shortest distances between the cup surface and the OCT-based disc margin were automatically calculated to determine the thickness and area of the minimum distance band (MDB ...

      Read Full Article
    6. Diagnostic performance of a novel 3D neuroretinal rim parameter for glaucoma using high-density volume scans

      Diagnostic performance of a novel 3D neuroretinal rim parameter for glaucoma using high-density volume scans

      Purpose To describe optical coherence tomography angiography (OCTA) findings in multifocal choroiditis (MFC) with active lesions and to characterize the concordance between the OCTA and other traditional imaging modalities. Design Reliability and validity analysis. Methods Patients with suspected choroidal neovascularization (CNV) or acute inflammatory lesions associated with MFC were assessed in this study. All participants underwent preliminary traditional multimodal imaging including color fundus photography, fundus autofluorescence, near-infrared reflectance imaging, spectral-domain optical coherence tomography, and fluorescence angiography (FA). The participants were prospectively recruited to perform OCTA. OCTA findings of active lesions were compared with other traditional imaging results. Vascular flow signal ...

      Read Full Article
    1-6 of 6
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (6 articles) Johannes F. de Boer
    2. (5 articles) Harvard University
    3. (5 articles) Teresa C. Chen
    4. (4 articles) Massachusetts Eye and Ear Infirmary
    5. (4 articles) VU University Amsterdam
    6. (3 articles) Massachusetts General Hospital
    7. (3 articles) Brett E. Bouma
    8. (3 articles) Benjamin J. Vakoc
    9. (1 articles) Vivek J. Srinivasan
    10. (1 articles) Heidelberg Spectralis
    11. (1 articles) UC Davis
    12. (1 articles) Robert J. Zawadzki
    13. (1 articles) Mehdi Azimipour
    14. (1 articles) John S. Werner
    15. (1 articles) Ravi S. Jonnal
  3. Popular Articles

  4. Picture Gallery

    Diagnostic performance of a novel 3D neuroretinal rim parameter for glaucoma using high-density volume scans Comprehensive Three-Dimensional Analysis of the Neuroretinal Rim in Glaucoma Using High-Density Spectral-Domain Optical Coherence Tomography Volume Scans Diagnostic Capability of Peripapillary 3D Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans Effects of Age, Race, and Ethnicity on the Optic Nerve and Peripapillary Region Using Spectral-Domain OCT 3D Volume Scans Diagnostic Capability of 3D Peripapillary Retinal Volume for Glaucoma Using Optical Coherence Tomography Customized Software Optoretinography: optical measurements of human cone and rod photoreceptor responses to light Nodular skin lesions: correlation of reflectance confocal microscopy (RCM) and optical coherence tomography (OCT) features OCT and Ophthalmology in the Age of Artificial Intelligence, Tuesday Oct 8, 2019 1:00P EDT Compensation for the Influence of Fluctuations in the Distance to the Object During Noncontact Probing in Spectral Domain Optical Coherence Tomography Pattern electroretinogram changes in patients with primary open-angle glaucoma in correlation with visual field and optical coherence tomography changes Objective evaluation of proliferative diabetic retinopathy using optical coherence tomography