1. Articles from L. de-Pablo-Gómez-de-Liaño

    1-4 of 4
    1. Assessment of changes in the macula and optic nerve head using optical coherence tomography in patients with attention deficit hyperactivity disorder

      Assessment of changes in the macula and optic nerve head using optical coherence tomography in patients with attention deficit hyperactivity disorder

      Introduction To assess if there are any differences in macular and papillary thickness using optical coherence tomography (OCT) in patients with attention deficit hyperactivity disorder (ADHD) compared with a control group, including if there are differences between ADHD patients with and without treatment. Methods Prospective observational study including 92 eyes of 46 patients divided into 2 groups: 46 eyes of 23 patients with ADHD, and a control group of 46 eyes of 23 healthy patients. The group of patients with ADHD was subdivided into those on treatment with methylphenidate (n = 28) and those not on treatment (n = 18). The macular ...

      Read Full Article
    2. Assessment of extraocular muscle thickness and correlation study using optical coherence tomography

      Assessment of extraocular muscle thickness and correlation study using optical coherence tomography

      Objective To report reference values for the horizontal rectus muscles thickness using Spectral Domain optical coherence tomography (SD-OCT), and to evaluate whether there are any correlations between the muscle thickness and gender, age, or axial length (AL). Material and methods A cross-sectional study was conducted on 131 right eyes of healthy subjects. The gender and age were recorded, and axial length was measured using an optical biometer. The medial rectus (MR) muscle thickness was measured at 7.2 and 9.2mm from the limbus, and the lateral rectus (LR) at 8.5 and 10.5mm from the limbus using OCT ...

      Read Full Article
    3. Agreement between Pentacam and optical coherence tomography in the assessment of iridocorneal angle width in a large healthy population

      Agreement between Pentacam and optical coherence tomography in the assessment of iridocorneal angle width in a large healthy population

      Purpose To analyze the agreement between Pentacam and optical coherence tomography (OCT) in the assessment of trabecular-iris angle (TIA) width in a large population of normal subjects. Methods A cross-sectional study was performed in 989 right eyes of 989 healthy subjects. The trabecular-iris angle (TIA) was measured in the temporal and nasal quadrants using the Pentacam (Oculus, Wetzlar, Germany), a device based on Scheimpflug technology and RTVue 100 OCT (Optovue, Fremont, CA, USA). Intraclass correlation coefficients (ICC) and Bland–Altman plots were used to evaluate agreement between these devices. Results Mean age was 49.1 ± 15.2 years (18–84 ...

      Read Full Article
      Mentions: Optovue
    4. Agreement between intraoperative measurements and optical coherence tomography of the limbus-insertion distance of the extraocular muscles

      Agreement between intraoperative measurements and optical coherence tomography of the limbus-insertion distance of the extraocular muscles

      Objective To assess the agreement between intraoperative measurements of the limbus-insertion distance of the extraocular muscles with those measured by spectral domain optical coherence tomography. Methods An analysis was made of a total of 67 muscles of 21 patients with strabismus. The limbus-insertion distance of the horizontal rectus muscles were measured using pre-operative SD-OCT and intra-operatively in 2 ways: 1) direct, after a conjunctival dissection in patients who underwent surgery, or 2) transconjunctival in patients who were treated with botulinum toxin, or in those who were not going to be operated. The intraclass correlation coefficient and Bland-Altman plots were calculated ...

      Read Full Article
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (1 articles) Optovue
    2. (1 articles) Institute of Applied Physics
    3. (1 articles) Grigory V. Gelikonov
    4. (1 articles) Gereon Hüttmann
    5. (1 articles) Hendrik Spahr
    6. (1 articles) Xincheng Yao
    7. (1 articles) Pavel A. Shilyagin
    8. (1 articles) Carl Zeiss Meditec
    9. (1 articles) Thorlabs
  3. Popular Articles

  4. Picture Gallery

    Agreement between intraoperative measurements and optical coherence tomography of the limbus-insertion distance of the extraocular muscles Agreement between Pentacam and optical coherence tomography in the assessment of iridocorneal angle width in a large healthy population Assessment of extraocular muscle thickness and correlation study using optical coherence tomography Assessment of changes in the macula and optic nerve head using optical coherence tomography in patients with attention deficit hyperactivity disorder Postdoctoral opening in optical instrumentation and retinal imaging at University of Illinois at Chicago Detection of intracranial hypertension in children using optical coherence tomography: a systematic review protocol Optical coherence tomography versus intravascular ultrasound for culprit lesion assessment in patients with acute myocardial infarction Insulin-like growth factor-1 levels predict myocardial injury and infarction after elective percutaneous coronary intervention: an optical coherence tomography study Short-term healing response after implantation of the thin-strut, fast-releasing sirolimus-eluting biodegradable polymer-coated Alex Plus stent: optical coherence tomography study Connector sensors for permittivity-based thrombus monitoring in extracorporeal life support Optical Coherence Tomography Angiography for Mapping Cerebral Microvasculature Based on Normalized Differentiation Analysis Determination and correction of aberrations in full field OCT using phase gradient autofocus by maximizing the likelihood function