1. Articles from Daren Hanumunthadu

    1-5 of 5
    1. Comparison of choroidal vessel thickness in children and adult eyes by enhanced-depth imaging optical coherence tomography imaging

      Comparison of choroidal vessel thickness in children and adult eyes by enhanced-depth imaging optical coherence tomography imaging

      AIM : To evaluate choroidal thickness, medium choroidal vessel thickness (MCVT) and large choroidal vessel thickness (LCVT) in normal children and adult subjects. METHODS : Manual measurements of subfoveal choroidal thickness (SFCT), MCVT and LCVT at subfoveal and 750 μm nasal and temporal to fovea locations were completed on enhanced-depth imaging optical coherence tomography (EDI-OCT) scans of normal children and adult subjects. RESULTS : Fifty adult and fifty-seven child subjects were included in the study (including 80 adult and 103 child eyes). Mean (±SD) SFCT of adult and children eyes in the study was 309.3±95.7 μm and 279.3±50 ...

      Read Full Article
    2. Agreement of swept-source and spectral-domain optical coherence-tomography retinal thickness measurements in neovascular age-related macular degeneration

      Agreement of swept-source and spectral-domain optical coherence-tomography retinal thickness measurements in neovascular age-related macular degeneration

      Changes in macular thickness measurements in neovascular age-related macular degeneration (nAMD) are thought to reflect disease activity, and can be used to guide treatment with antiangiogenic agents. 1 Both spectral-domain optical coherence tomography (SD-OCT) and the more recently introduced swept-source optical coherence tomography (SS-OCT) have onboard segmentation algorithms that deliver automated retinal thickness measurements. Agreement between OCT derived macular thickness measurements is critical for monitoring of patients if these modalities are to be used interchangeably. This prospective cross-sectional study sought to determine the limits of agreement between SD-OCT (Spectralis; Heidelberg Engineering) and SS-OCT (DRI OCT-1 Atlantis; Topcon Medical Systems) in ...

      Read Full Article
    3. Impact of retinal pigment epithelium pathology on spectral-domain optical coherence tomography-derived macular thickness and volume metrics and their intersession repeatability

      Impact of retinal pigment epithelium pathology on spectral-domain optical coherence tomography-derived macular thickness and volume metrics and their intersession repeatability

      Background To determine the impact of retinal pigment epithelium (RPE) pathology on intersession repeatability of retinal thickness and volume metrics derived from Spectralis spectral-domain optical coherence tomography (SD-OCT). Design Prospective cross-sectional single centre study. Participants 56 eyes of 56 subjects were divided into 3 groups: (A) normal RPE band (25 eyes), (B) RPE elevation: macular soft drusen (13 eyes) and (C) RPE attenuation: geographic atrophy or inherited retinal diseases (18 eyes). Methods Each subject underwent three consecutive follow-up macular raster scans (61 B-scans at 119 micron separation) at 1-month intervals. Main outcome measures Retinal thicknesses and volumes for each zone ...

      Read Full Article
    4. Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

      Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration

      Background The aim was to determine the intrasession repeatability of swept-source optical coherence tomography (SS-OCT)-derived retinal and choroidal thickness measurements in eyes with neovascular age-related macular degeneration (nAMD). Methods A prospective study consisting of patients with active nAMD enrolled in the Distance of Choroid Study at Moorfields Eye Hospital, London. Patients underwent three 12×9 mm macular raster scans using the deep range imaging (DRI) OCT-1 SS-OCT (Topcon) device in a single imaging session. Retinal and choroidal thicknesses were calculated for the ETDRS macular subfields. Repeatability was calculated according to methods described by Bland and Altman. Results 39 eyes ...

      Read Full Article
    5. Spectral-domain optical coherence tomography retinal and choroidal thickness metric repeatability in age related macular degeneration - American Journal of Ophthalmology

      Spectral-domain optical coherence tomography retinal and choroidal thickness metric repeatability in age related macular degeneration - American Journal of Ophthalmology

      Purpose To determine the intrasession repeatability of spectral domain-OCT (SD-OCT)-derived macular retinal and choroidal metrics in patients with neovascular age-related macular degeneration (nAMD) in the Distance of Choroid Study (DOCS) Design Validity and reliability analysis Methods Enrolled patients underwent repeated SD-OCT imaging using the Spectralis OCT. A single technician certified for clinical trials took 3 macular volume scans. Retinal thicknesses were calculated for each of the nine Early Treatment Diabetic Retinopathy Study (ETDRS) macular subfields. Center-point thickness and total macular volume were also included in the analysis. Manual subfoveal choroidal thickness measurements were made by a masked observer. Results ...

      Read Full Article
    1-5 of 5
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Praveen J. Patel
    2. (2 articles) Adnan Tufail
    3. (2 articles) Topcon Medical Systems
    4. (2 articles) Boston University
    5. (2 articles) David A. Boas
    6. (1 articles) University College London
    7. (1 articles) L V Prasad Eye Institute
    8. (1 articles) Fred K. Chen
    9. (1 articles) Heidelberg Engineering
    10. (1 articles) Medical University of Vienna
    11. (1 articles) Korea University
    12. (1 articles) University of Ulsan
    13. (1 articles) University College London
    14. (1 articles) Baylor College of Medicine
    15. (1 articles) Semmelweis University
    16. (1 articles) Christoph K. Hitzenberger
    17. (1 articles) Pearse A. Keane
  3. Popular Articles

  4. Picture Gallery

    Spectral-domain optical coherence tomography retinal and choroidal thickness metric repeatability in age related macular degeneration - American Journal of Ophthalmology Repeatability of swept-source optical coherence tomography retinal and choroidal thickness measurements in neovascular age-related macular degeneration Impact of retinal pigment epithelium pathology on spectral-domain optical coherence tomography-derived macular thickness and volume metrics and their intersession repeatability Agreement of swept-source and spectral-domain optical coherence-tomography retinal thickness measurements in neovascular age-related macular degeneration Comparison of choroidal vessel thickness in children and adult eyes by enhanced-depth imaging optical coherence tomography imaging Comparative study between intravitreal ranibizumab and triamcinolone treatment of diabetic macular edema as regard to optical coherence tomography changes and visual acuity What’s New in Optical Coherence Tomography Angiography for Glaucoma (Book Chapter) Looking into the Future: Optical Coherence Tomography for the Assessment of Cardiac Allograft Vasculopathy Effects of Age on Peripapillary and Macular Vessel Density Determined Using Optical Coherence Tomography Angiography in Healthy Eyes Deep Neural Network Regression for Automated Retinal Layer Segmentation in Optical Coherence Tomography Images In-Stent Restenosis Lesion Morphology Related to Repeat Stenting Underexpansion as Evaluated by Optical Coherence Tomography Measurement of granule layer thickness in a spouted bed coating process via optical coherence tomography