1. Articles from Yuan Zhou

    1-5 of 5
    1. 3D imaging of proximal caries in posterior teeth using optical coherence tomography

      3D imaging of proximal caries in posterior teeth using optical coherence tomography

      Optical coherence tomography (OCT) can create cross-sectional images of tooth without X-ray exposure. This study aimed to investigate the diagnostic accuracy of 3D imaging of OCT for proximal caries in posterior teeth. Thirty-six human molar teeth with 51 proximal surfaces visibly 6 intact, 16 slightly demineralized, and 29 distinct carious changes were mounted to take digital radiographs and 3D OCT images. The sensitivity, specificity and area under the receiver operating characteristic curve (AUC) for the diagnosis of enamel caries and dentin caries were calculated to quantify the diagnostic ability of 3D OCT in comparison with digital radiography. Diagnostic accuracy was ...

      Read Full Article
    2. Assessment of root caries under wet and dry conditions using swept-source optical coherence tomography (SS-OCT)

      Assessment of root caries under wet and dry conditions using swept-source optical coherence tomography (SS-OCT)

      The purpose of this study was to compare optical properties of root caries under two observing conditions using swept-source optical coherence tomography (SS-OCT). In vitro and natural root caries were observed by SS-OCT under wet and dry conditions, followed by confocal laser scanning microscope (CLSM) and transverse microradiography (TMR). Signal intensity (SI), distance between SI peaks (SI-distance) and optical lesion depth were obtained from OCT. Lesion depth was measured from CLSM; lesion depth (LD TMR ) and mineral loss (ML) were obtained from TMR. In vitro root caries under wet and dry conditions showed different OCT images and SI patterns. Lesion ...

      Read Full Article
    3. Optical analysis of enamel and dentin caries in relation to mineral density using swept-source optical coherence tomography

      Optical analysis of enamel and dentin caries in relation to mineral density using swept-source optical coherence tomography

      The aim of this study was to evaluate the signal intensity and signal attenuation of swept source optical coherence tomography (SS-OCT) for dental caries in relation to the variation of mineral density. SS-OCT observation was performed on the enamel and dentin artificial demineralization and on natural caries. The artificial caries model on enamel and dentin surfaces was created using Streptococcus mutans biofilms incubated in an oral biofilm reactor. The lesions were centrally cross sectioned and SS-OCT scans were obtained in two directions to construct a three-dimensional data set, from the lesion surface (sagittal scan) and parallel to the lesion surface ...

      Read Full Article
    4. Assessment of bacterial demineralization around composite restorations using swept-source optical coherence tomography (SS-OCT)

      Assessment of bacterial demineralization around composite restorations using swept-source optical coherence tomography (SS-OCT)

      Objective To observe the bacterial demineralization of the enamel and dentin around composite restorations bonded with one-step and two-step self-etch adhesive systems using swept-source optical coherence tomography (SS-OCT). Methods Forty class V cavities (2.5-mm surface diameter, 2.0-mm maximum depth) were prepared on cervical areas of 20 human molars. The specimens were either treated with one-step adhesive (Clearfil Tri-S Bond ND Quick; TS) or two-step adhesive (Clearfil SE Bond; SE), restored with a flowable resin composite (Estelite Flow Quick). Specimens in the demineralized group were incubated for 2 weeks after Streptococcus mutans biofilm formation, while specimens in the control ...

      Read Full Article
    5. Rapid and high-resolution imaging of human liver specimens by full-field optical coherence tomography

      Rapid and high-resolution imaging of human liver specimens by full-field optical coherence tomography

      We report rapid and high-resolution tomographic en face imaging of human liver specimens by full-field optical coherence tomography (FF-OCT). First, the arrangement of the FF-OCT system was described and the performance of the system was measured. The measured axial and lateral resolutions of the system are 0.8 and 0.9     μ m , respectively. The system has a sensitivity of ∼ 60     dB and can achieve an imaging rate of 7 fps and a penetration depth of ∼ 80     μ m . The histological structures of normal liver can be seen clearly in the en face tomographic images, including central veins, cords of hepatocytes separated ...

      Read Full Article
    1-5 of 5
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) National Center for Geriatrics and Gerontology in Japan
    2. (4 articles) Junji Tagami
    3. (4 articles) Yasushi Shimada
    4. (4 articles) Alireza Sadr
    5. (4 articles) Yasunori Sumi
    6. (3 articles) Tokyo Medical & Dental University
    7. (2 articles) University of Washington
    8. (1 articles) University of Hong Kong
    9. (1 articles) Nanjing University of Science and Technology
    10. (1 articles) Wanrong Gao
    11. (1 articles) Capital Medical University
    12. (1 articles) Medical University of Vienna
    13. (1 articles) New York Eye and Ear Infirmary
    14. (1 articles) Nanjing University of Science and Technology
    15. (1 articles) Bern University Hospital
    16. (1 articles) Martin S. Zinkernagel
  3. Popular Articles

  4. Picture Gallery

    Rapid and high-resolution imaging of human liver specimens by full-field optical coherence tomography Assessment of bacterial demineralization around composite restorations using swept-source optical coherence tomography (SS-OCT) Optical analysis of enamel and dentin caries in relation to mineral density using swept-source optical coherence tomography Assessment of root caries under wet and dry conditions using swept-source optical coherence tomography (SS-OCT) 3D imaging of proximal caries in posterior teeth using optical coherence tomography Retinal Vascular Features in Ocular Blunt Trauma by Optical Coherence Tomography Angiography Non-invasive imaging of a choroidal macrovessel Correlation between optical coherence tomography, multifocal electroretinogram findings and visual acuity in diabetic macular edema Digital Wavefront Sensing Ciliary body length revisited by anterior segment optical coherence tomography: implications for safe access to the pars plana for intravitreal injections Evaluation of retinal vascular structure after epiretinal membrane surgery by optical coherence tomography angiography Bivalirudin vs. Heparin on Radial Artery Thrombosis during Transradial Coronary Intervention: An Optical Coherence Tomography Study