1. Articles from Bartlomiej Kaluzny

    1-4 of 4
    1. Assessment of the influence of viscoelasticity of cornea in animal ex vivo model using air‐puff optical coherence tomography and corneal hysteresis

      Assessment of the influence of viscoelasticity of cornea in animal ex vivo model using air‐puff optical coherence tomography and corneal hysteresis

      Application of the air‐puff swept source OCT (SS‐OCT) instrument to determine the influence of viscoelasticity on the relation between overall the air‐puff force and corneal apex displacement of porcine corneas ex vivo is demonstrated. Simultaneous recording of time‐evolution of the tissue displacement and air pulse stimulus allows obtaining valuable information related in part to the mechanical properties of the cornea. A novel approach based on quantitative analysis of the corneal hysteresis of OCT data is presented. The corneal response to the air pulse is assessed for different well‐controlled IOP levels and for the progression of ...

      Read Full Article
    2. Non-contact investigation of the corneal biomechanics with air-puff swept source optical coherence tomography

      Non-contact investigation of the corneal biomechanics with air-puff swept source optical coherence tomography

      In this paper, we use swept source optical coherence tomography combined with air-puff module (air-puff SS-OCT) to investigate the properties of the cornea. During OCT measurement the cornea was stimulated by short, air pulse, and corneal response was recorded. In this preliminary study, the air-puff SS-OCT instrument was applied to measure behavior of the porcine corneas under varied, well-controlled intraocular pressure conditions. Additionally, the biomechanical response of the corneal tissue before, during and after crosslinking procedure (CXL) was assessed. Air-puff swept source OCT is a promising tool to extract information about corneal behavior as well as to monitor and assess ...

      Read Full Article
    3. New Directions in Ophthalmic Optical Coherence Tomography

      New Directions in Ophthalmic Optical Coherence Tomography

      The rapid development of optical coherence tomography (OCT) and its ophthalmic applications has resulted in the emergence of new laboratory and commercial systems that vary in performance and functionality. The introduction of high-speed imaging capabilities has abrogated the primary limitation of early OCT technology by providing in vivo three-dimensional volumetric reconstructions of both anterior and posterior segments of the human eye within reasonable time constraints. Currently, high-speed swept source OCT technology has made it possible to achieve OCT acquisition speeds of several million A-scans/s. Another direction of OCT development includes the introduction of adaptive optics to imaging of the ...

      Read Full Article
    4. Swept source OCT imaging of human anterior segment at 200 kHz

      Karol Karnowski, Michalina Gora, Bartlomiej Kaluzny et al. We present applicability of the high speed swept-source optical coherence tomography for in vivo imaging of the anterior segment of the human eye. Three dimensional imaging of the cornea with reduced motion artifacts is possible by using swept source with Fourier domain mode locking operating at 200 ... [Proc. SPIE 7163, 716308 (2009)] published Wed Feb 18, 2009.
      Read Full Article
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Nicolaus Copernicus University
    2. (4 articles) Maciej Wojtkowski
    3. (3 articles) Bartlomiej J. Kaluzny
    4. (3 articles) Karol Karnowski
    5. (2 articles) Ireneusz Grulkowski
    6. (1 articles) Ludwig Maximilian University of Munich
    7. (1 articles) Robert A. Huber
    8. (1 articles) Michalina J. Góra
    9. (1 articles) Andrzej A. Kowalczyk
    10. (1 articles) Maciej Szkulmowski
    11. (1 articles) Medical University of Vienna
    12. (1 articles) Tianjin University
    13. (1 articles) Wenzhou Medical College
    14. (1 articles) Sebastian M. Waldstein
    15. (1 articles) Ursula Schmidt-Erfurth
    16. (1 articles) Optovue
    17. (1 articles) Thorlabs
    18. (1 articles) Heidelberg Spectralis
    19. (1 articles) Zeiss Cirrus HD-OCT
    20. (1 articles) Zeiss Visante OCT
  3. Popular Articles

  4. Picture Gallery

    New Directions in Ophthalmic Optical Coherence Tomography Non-contact investigation of the corneal biomechanics with air-puff swept source optical coherence tomography Assessment of the influence of viscoelasticity of cornea in animal ex vivo model using air‐puff optical coherence tomography and corneal hysteresis In-Vitro MPI-guided IVOCT catheter tracking in real time for motion artifact compensation Fast Retinal Segmentation Based on the Wave Algorithm Optical coherence tomography angiography findings in axial spondylarthritis Foveal Avascular Zone Measurement Via Optical Coherence Tomography Angiography and its Relationship with the Visual Field in Eyes with Open-angle Glaucoma Retinal blood flow reduction in normal-tension glaucoma with single-hemifield damage by Doppler optical coherence tomography Optic Disc and Macular Vessel Density Measured by Optical Coherence Tomography Angiography in Open-Angle and Angle-Closure Glaucoma Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurementsv Incidence and clinical impact of thrombus after stent implantation in patients with ST-segment elevation myocardial infarction: an optical coherence tomography study Evaluating Retinal Angiomatous Proliferation With Optical Coherence Tomography Angiography