1. Articles from Tetsuo Horimatsu

    1-4 of 4
    1. Impact of low tissue backscattering by optical coherence tomography on endothelial function after drug-eluting stent implantation

      Impact of low tissue backscattering by optical coherence tomography on endothelial function after drug-eluting stent implantation

      This study evaluated the impact of optical coherence tomography (OCT)-derived low-backscattered tissue on mid-term coronary endothelial function after drug-eluting stent (DES) implantation. Although OCT enables detailed in vivo evaluation of neointimal tissue characterization after DES implantation, its association with physiological vascular healing response is unclear. Thirty-three stable angina pectoris patients underwent OCT examination and endothelial function testing with intracoronary infusion of incremental doses of acetylcholine 8-month after DES implantation in a single lesion of the left anterior descending artery. Neointimal tissue was classified into two patterns based on the predominant OCT light backscatter: high backscatter and low backscatter. Although ...

      Read Full Article
      Mentions: Kenichi Fujii
    2. Comparing the vascular response in implantation of self-expanding, bare metal nitinol stents or paclitaxel-eluting nitinol stents in superficial femoral artery lesions: a serial optical frequency domain imaging study

      Comparing the vascular response in implantation of self-expanding, bare metal nitinol stents or paclitaxel-eluting nitinol stents in superficial femoral artery lesions: a serial optical frequency domain imaging study

      Aims: This study sought to investigate differences in vascular response between self-expanding bare metal nitinol stents (BMS) and paclitaxel-eluting nitinol stents (PES), in superficial femoral artery (SFA) disease, using optical frequency domain imaging (OFDI). Methods and results: Six months after stent implantation, follow-up quantitative vascular angiography (QVA) and OFDI assessment were scheduled to evaluate vascular response. Volume index (VI) was defined as volume divided by stent length. The primary endpoint was OFDI-derived late lumen area loss, defined as lumen VI post stent implantation minus lumen VI at follow-up. A total of 28 SFA lesions were analysed, with cases randomised to ...

      Read Full Article
    3. Ex Vivo Assessment of Neointimal Characteristics After Drug-eluting Stent Implantation: Optical Coherence Tomography and Histopathology Validation Study

      Ex Vivo Assessment of Neointimal Characteristics After Drug-eluting Stent Implantation: Optical Coherence Tomography and Histopathology Validation Study

      Background Optical coherence tomography (OCT) is one of the tools trying to distinguish neoatherosclerosis from other neointimal tissue but its role has to be still validated. This study evaluated the diagnostic accuracy of OCT for characterization of lipid-atherosclerotic neointima following drug-eluting stent (DES) implantation. Methods Twelve stented coronary arteries from the 7 autopsy hearts were imaged by OCT. These OCT images were compared with histology. By OCT, the morphological appearances of neointima were classified into three patterns: homogeneous pattern, heterogeneous pattern with visible strut, or heterogeneous pattern with invisible strut. Results Of 21 histological cross-sections, 6 were categorized as homogeneous ...

      Read Full Article
    4. Tissue Characterization of In-Stent Neointima Using Optical Coherence Tomography in the Late Phase After Bare-Metal Stent Implantation – An Ex Vivo Validation Study –

      Tissue Characterization of In-Stent Neointima Using Optical Coherence Tomography in the Late Phase After Bare-Metal Stent Implantation – An Ex Vivo Validation Study –

      Background: We performed an ex vivo study to investigate optical coherence tomography (OCT) imaging for differentiating several types of neointimal tissue during the later phases after bare-metal stent (BMS) implantation as compared with histologic results. Methods and Results: OCT imaging was performed in 6 autopsy hearts for 10 BMS with implant duration >4 years. OCT qualitative neointimal tissue characterization was based on tissue structure and classified as homogeneous pattern, heterogeneous pattern with visible struts, or heterogeneous pattern with invisible struts. Corresponding histological analyses of each 2-mm cross-section of the entire BMS were performed. Of 81 cross-sections, histological analysis revealed that ...

      Read Full Article
      Mentions: Abbot Kenichi Fujii
    1-4 of 4
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) Kenichi Fujii
    2. (1 articles) Stanford University
    3. (1 articles) Peter J. Fitzgerald
    4. (1 articles) Yasuhiro Honda
    5. (1 articles) Abbot
    6. (1 articles) University of Copenhagen
    7. (1 articles) Center for Ophthalmic Optics and Lasers
    8. (1 articles) FDA
    9. (1 articles) Oregon Health & Science University
    10. (1 articles) SUNY at Stony Brook
    11. (1 articles) University College London
    12. (1 articles) David Huang
    13. (1 articles) Axel Petzold
    14. (1 articles) Perimeter Medical Imaging
    15. (1 articles) Carl Zeiss Meditec
  3. Popular Articles

  4. Picture Gallery

    Tissue Characterization of In-Stent Neointima Using Optical Coherence Tomography in the Late Phase After Bare-Metal Stent Implantation – An Ex Vivo Validation Study – Ex Vivo Assessment of Neointimal Characteristics After Drug-eluting Stent Implantation: Optical Coherence Tomography and Histopathology Validation Study Comparing the vascular response in implantation of self-expanding, bare metal nitinol stents or paclitaxel-eluting nitinol stents in superficial femoral artery lesions: a serial optical frequency domain imaging study Impact of low tissue backscattering by optical coherence tomography on endothelial function after drug-eluting stent implantation EARLY SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY BIOMARKERS TO CONFIRM FELLOW EYE CHANGES IN ASYMMETRIC TYPE-2 MACULAR TELANGIECTASIA Relative Postpartum Retinal Vasoconstriction Detected With Optical Coherence Tomography Angiography 1.1 μm waveband tunable laser using emission-wavelength-controlled InAs quantum dots for swept-source optical coherence tomography applications Retinal nerve fibre layer and peripapillary vascular density by optical coherence tomography angiography in schizophrenia Livelayer: A Semi-Automatic Software Program for Segmentation of Layers and Diabetic Macular Edema in Optical Coherence Tomography Images Long-term progression of myopic maculopathy in degenerative myopia as imaged by SD-OCT and IR imaging Postdoctoral Research Fellowship position  in the Center for Ophthalmic Optics and Lasers, Casey Eye Institute, Oregon Health & Science University Perimeter Medical Imaging AI Announces U.S. FDA 510(k) Clearance for OCT Imaging System