    1. Intra- and interobserver reproducibility of Bruch's membrane opening minimum rim width measurements with spectral domain optical coherence tomography

      Intra- and interobserver reproducibility of Bruch's membrane opening minimum rim width measurements with spectral domain optical coherence tomography

      Purpose To investigate the reproducibility of Bruch's membrane opening minimum rim width (BMO-MRW) and retinal nerve fibre layer thickness (RNFLT) measurements using spectral domain optical coherence tomography (SD-OCT). Additionally, to investigate the reproducibility of BMO area measurements and fovea to BMO centre (FoBMO) angle. Methods Participants were healthy subjects ( n = 30) and patients with glaucoma ( n = 26). One eye of each participant was scanned to obtain optic nerve head (24 radial B-scans) and peripapillary (one circular B-scan) images by three independent examiners. Additionally, one examiner imaged each participant three times on the same day. Intra- and interobserver reproducibilities were ...

      Read Full Article
    2. Association between Intraocular Pressure and Rates of Retinal Nerve Fiber Layer Loss Measured by Optical Coherence Tomography

      Association between Intraocular Pressure and Rates of Retinal Nerve Fiber Layer Loss Measured by Optical Coherence Tomography

      Purpose To evaluate the relationship between intraocular pressure (IOP) and rates of retinal nerve fiber layer (RNFL) thickness change over time measured by spectral-domain (SD) optical coherence tomography (OCT). Design Observational cohort study. Participants The study involved 547 eyes of 339 patients followed up for an average of 3.9±0.9 years. Three hundred eight (56.3%) had a diagnosis of glaucoma and 239 (43.7%) were considered glaucoma suspects. Methods All eyes underwent imaging using the Spectralis SD OCT (Heidelberg Engineering GmbH, Heidelberg, Germany), along with IOP measurements and standard automated perimetry (SAP). Glaucoma progression was defined as ...

      Read Full Article
    3. The Relative Odds of Progressing by Structural and Functional Tests in Glaucoma

      The Relative Odds of Progressing by Structural and Functional Tests in Glaucoma

      Purpose : The purpose of this study was to evaluate the effect of disease severity and number of tests acquired during follow-up on the relative odds of identifying progression by structural or functional tests in glaucoma. Methods : This was an observational cohort study involving 462 eyes of 305 patients with glaucoma and 62 eyes of 49 healthy subjects. Glaucoma patients and healthy subjects were followed for an average of 3.6 ± 0.9 and 3.8 ± 0.9 years, with a median (interquantile range) of 8 (6–9) and 7 (6–8) visits, respectively. At each visit, subjects underwent visual field ...

      Read Full Article
    4. The Use of Spectral-Domain Optical Coherence Tomography to Detect Glaucoma Progression

      The Use of Spectral-Domain Optical Coherence Tomography to Detect Glaucoma Progression

      Detection of progression and measurement of rates of change is at the core of glaucoma management, and the use of Spectral Domain Optical Coherence Tomography (SD-OCT) has significantly improved our ability to evaluate change in the disease. In this review, we critically assess the existing literature on the use of SD-OCT for detecting glaucoma progression and estimating rates of change. We discuss aspects related to the reproducibility of measurements, their accuracy to detect longitudinal change over time, and the effect of aging on the ability to detect progression. In addition, we discuss recent studies evaluating the use of combined structure ...

      Read Full Article
    5. Spectral-Domain Optical Coherence Tomography for Glaucoma Diagnosis

      Spectral-Domain Optical Coherence Tomography for Glaucoma Diagnosis

      Identification of structural damage to the optic nerve and retinal nerve fiber layer (RNFL) is an essential component of diagnosis and management of glaucoma. The introduction of spectral-domain OCT (SD-OCT) has allowed objective quantification of damage to these structures with unprecedented resolution. In addition, recent attention has been directed towards imaging the macular area for quantifying loss of neural tissue caused by the disease. Many studies have evaluated and compared the diagnostic accuracies of a variety of parameters that can be obtained from imaging these areas of the ocular fundus. In this article, we critically review the existing literature evaluating ...

      Read Full Article
    1-5 of 5
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (4 articles) Felipe A. Medeiros
    2. (2 articles) Universidade Federal de São Paulo
    3. (2 articles) UCSD
    4. (2 articles) Linda M. Zangwill
    5. (2 articles) Robert N. Weinreb
    6. (1 articles) UC Davis
    7. (1 articles) Christopher A. Girkin
    8. (1 articles) Alexandre S. C. Reis
    9. (1 articles) Jeffrey M. Liebmann
  3. Popular Articles

  4. Picture Gallery

    Spectral-Domain Optical Coherence Tomography for Glaucoma Diagnosis The Use of Spectral-Domain Optical Coherence Tomography to Detect Glaucoma Progression The Relative Odds of Progressing by Structural and Functional Tests in Glaucoma Association between Intraocular Pressure and Rates of Retinal Nerve Fiber Layer Loss Measured by Optical Coherence Tomography Intra- and interobserver reproducibility of Bruch's membrane opening minimum rim width measurements with spectral domain optical coherence tomography The multi-spectral signal properties of multiple reference optical coherence tomography (Thesis) Calibration-free time-stretch optical coherence tomography with large imaging depth Does Projection Artifact Removal Improve Visualization of Images in Optical Coherence Tomography Angiography? Spectral‐domain optical coherence tomography of retinal vessels in Waldenström's macroglobulinemia Optical coherence tomography imaging of oral mucosa bullous diseases: a preliminary study The use of anterior segment optical coherence tomography (ASOCT) in demonstrating recurrence of vitreoretinal lymphoma (VRL) in the anterior vitreous PHD POSITION – OPTICAL COHERENCE TOMOGRAPHY ON AGRO-FOOD PRODUCTS