1. Articles from Nikki P. Lee

    1-3 of 3
    1. Tri-band optical coherence tomography for lipid and vessel spectroscopic imaging

      Tri-band optical coherence tomography for lipid and vessel spectroscopic imaging

      Optical coherence tomography (OCT) has been utilized for various functional imaging applications. One of its highlights comes from spectroscopic imaging, which can simultaneously obtain both morphologic and spectroscopic information. Assisting diagnosis and therapeutic intervention of coronary artery disease is one of the major directions in spectroscopic OCT applications. Previously Tanaka et al. have developed a spectral domain OCT (SDOCT) to image lipid distribution within blood vessel [1]. In the meantime, Fleming et al. have demonstrated optical frequency domain imaging (OFDI) by a 1.3-μm swept source and quadratic discriminant analysis model [2]. However, these systems suffered from burdensome computation ...

      Read Full Article
    2. Tri-band spectroscopic optical coherence tomography based on optical parametric amplification for lipid and vessel visualization

      Tri-band spectroscopic optical coherence tomography based on optical parametric amplification for lipid and vessel visualization

      A tri-band spectroscopic optical coherence tomography (SOCT) system has been implemented for visualization of lipid and blood vessel distribution. The tri-band swept source, which covers output spectrum in 1.3, 1.5, and 1.6μ m wavelength windows, is based on a dual-band Fourier domain mode-locked laser and a fiber optical parametric amplifier. This tri-band SOCT can further differentiate materials, e.g., lipid and artery, qualitatively by contrasting attenuation coefficients difference within any two of these bands. Furthermore, ex vivo imaging of both porcine artery with artificial lipid plaque phantom and mice with coronary artery disease were demonstrated to showcase ...

      Read Full Article
    3. Simultaneous dual-band optical coherence tomography for endoscopic applications

      Simultaneous dual-band optical coherence tomography for endoscopic applications

      Dual-band optical coherence tomography (OCT) can greatly enhance the imaging contrast with potential applications in functional (spectroscopic) analysis. A new simultaneous dual-band Fourier domain mode-locked swept laser configuration for dual-band OCT is reported. It was based on a custom-designed dual-channel driver to synchronize two different wavelength bands at 1310 and 1550 nm, respectively. Two lasing wavelengths were swept simultaneously from 1260 to 1364.8 nm for the 1310-nm band and from 1500 to 1604 nm for the 1550-nm band at an A-scan rate of 45 kHz. Broadband wavelength-division multiplexing was utilized to couple two wavelength bands into a common catheter ...

      Read Full Article
    1-3 of 3
  1. Categories

    1. Applications:

      Art, Cardiology, Dentistry, Dermatology, Developmental Biology, Gastroenterology, Gynecology, Microscopy, NDE/NDT, Neurology, Oncology, Ophthalmology, Other Non-Medical, Otolaryngology, Pulmonology, Urology
    2. Business News:

      Acquisition, Clinical Trials, Funding, Other Business News, Partnership, Patents
    3. Technology:

      Broadband Sources, Probes, Tunable Sources
    4. Miscellaneous:

      Jobs & Studentships, Student Theses, Textbooks
  2. Topics in the News

    1. (3 articles) University of Hong Kong
    2. (3 articles) Kenneth K. Y. Wong
    3. (2 articles) Massachusetts General Hospital
    4. (1 articles) Harvard University
    5. (1 articles) The Chinese University of Hong Kong
    6. (1 articles) University of Miami
    7. (1 articles) VU University Amsterdam
    8. (1 articles) David A. Boas
    9. (1 articles) Brett E. Bouma
    10. (1 articles) Johannes F. de Boer
    11. (1 articles) Frank D. Verbraak
    12. (1 articles) Apollo Medical Optics
  3. Popular Articles

  4. Picture Gallery

    Simultaneous dual-band optical coherence tomography for endoscopic applications Tri-band spectroscopic optical coherence tomography based on optical parametric amplification for lipid and vessel visualization Tri-band optical coherence tomography for lipid and vessel spectroscopic imaging Optical Coherence Tomography: Critical Tool to Manage Expectations after Cataract Extraction Improving the characterization of ex vivo human brain optical properties using high numerical aperture optical coherence tomography by spatially constraining the confocal parameters Choroidal, macular and ganglion cell layer thickness assessment in Caucasian children measured with spectral domain optical coherence tomography Examination of retinal vascular density changes via optical coherence tomography angiography in patients with glaucoma 3D reconstruction of coronary artery bifurcations from coronary angiography and optical coherence tomography: feasibility, validation, and reproducibility Age- and refraction-related changes in anterior segment anatomical structures measured by swept-source anterior segment OCT The evaluation of juvenile ocular hypertension by optical coherence tomography angiography Superficial capillary perfusion on optical coherence tomography angiography differentiates moderate and severe nonproliferative diabetic retinopathy Autologous neurosensory free-flap retinal transplantation for refractory chronic macular hole—outcomes evaluated by OCT, microperimetry, and multifocal electroretinography