1. Repeatability of Cornea and Sublayer Thickness Measurements Using Optical Coherence Tomography in Corneas of Anomalous Refractive Status

    Repeatability of Cornea and Sublayer Thickness Measurements Using Optical Coherence Tomography in Corneas of Anomalous Refractive Status

    PURPOSE: To assess the repeatability of epithelial, stromal, and total corneal thickness measurements with spectral-domain optical coherence tomography (SD-OCT; RTVue-XR; Optovue, Inc., Fremont, CA) in patients with myopia, keratoconus, and corneas after transepithelial photorefractive keratectomy (PRK), small incision lenticule extraction (SMILE), and femtosecond laser–assisted in situ keratomileusis (FS-LASIK). METHODS: A total of 352 eyes of 352 patients (75 myopic, 68 post-transepithelial PRK, 61 post-SMILE, 75 post-FS-LASIK, 20 mild keratoconus, and 53 advanced keratoconus eyes) were included. The epithelial, stromal, and total corneal thickness were recorded from the pachymetric map in the following four zones: (1) central 2-mm region, (2 ...