1. Diagnostic Capability of 3D Peripapillary Retinal Volume for Glaucoma Using Optical Coherence Tomography Customized Software

    Diagnostic Capability of 3D Peripapillary Retinal Volume for Glaucoma Using Optical Coherence Tomography Customized Software

    Précis: The diagnostic capability of peripapillary retinal volume is similar to peripapillary retinal nerve fiber layer thickness for diagnosing glaucoma, but with fewer artifacts. Purpose: To compare the diagnostic capability of three-dimensional (3D) peripapillary retinal volume (RV) versus two-dimensional (2D) peripapillary retinal nerve fiber layer (RNFL) thickness for open-angle glaucoma . Patients and Methods: A retrospective cross-sectional analysis was conducted. A total of 180 subjects [113 open-angle glaucomas (OAG), 67 normal participants] had spectral domain optical coherence tomography (OCT) volume scans and RNFL thickness measurements. Peripapillary RV values were calculated using a custom-designed program with 4 circumpapillary annuli (CA): CA1 ...

    Read Full Article

    Login to comment.