1. Optical Coherence Tomography and Retinal Thickness Analyzer Features of Spontaneous Resolution of Vitreomacular Traction Syndrome: A Case Report

    Optical Coherence Tomography and Retinal Thickness Analyzer Features of Spontaneous Resolution of Vitreomacular Traction Syndrome: A Case Report

    Purpose To report optical coherence tomography (OCT) and retinal thickness analyzer (RIA) findings in a case of spontaneous resolution of vitreomacular traction syndrome. METHODS Qualitative and quantitative analysis of the macular region was performed with OCT and RTA. Results In the left eye of a 34-year-old woman with blurred vision, OCT and RTA examination showed a discrete linear signal anterior to the retina with attachment at the macula and secondary cystoid macular changes. OCT and RTA examination showed an increase in macular thickness (350 μm). Six months later the patient showed a spontaneous complete recovery of visual acuity. Vitreomacular traction ...

    Read Full Article