Fully automated dual-resolution serial optical coherence tomography aimed at diffusion MRI validation in whole mouse brains

An automated dual-resolution serial optical coherence tomography (2R-SOCT) scanner is developed. The serial histology system combines a low-resolution (25 μm / voxel) 3 × OCT with a high-resolution (1.5 μm / voxel) 40 × OCT to acquire whole mouse brains at low resolution and to target specific regions of interest (ROIs) at high resolution. The 40 × ROIs positions are selected either manually by the microscope operator or using an automated ROI positioning selection algorithm. Additionally, a multimodal and multiresolution registration pipeline is developed in order to align the 2R-SOCT data onto diffusion MRI (dMRI) data acquired in the same ex vivo mouse brains ...