1. MACULAR GANGLION CELL LAYER THICKNESS MEASUREMENT BY SD-OCT IN NON GLAUCOMATOUS MYOPIC EYE AND ITS CORRELATION WITH SPHERICAL EQUIVALENT AND AXIAL LENGTH

    MACULAR GANGLION CELL LAYER THICKNESS MEASUREMENT BY SD-OCT IN NON GLAUCOMATOUS MYOPIC EYE AND ITS CORRELATION WITH SPHERICAL EQUIVALENT AND AXIAL LENGTH

    Purpose: To evaluate macular ganglion cell layer thickness in non glaucomatous myopic eye and its correlation with spherical equivalent and axial length. Material and methods : A Cross sectional observational study was carried out in 50 eyes who were reported myopes. A detailed ophthalmic examination was done and participants having raised IOP and field defects were excluded. The selected candidates were subjected to ganglion cell complex study by SD-OCT and their relationship against myopic refractive equivalents and axial length was evaluated. Result: Eligible subjects were in the age group of 18- 35 years. Out of the 50 eyes evaluated, 40% showed ...