1. Local Determinants of Thrombus Formation Following Sirolimus-Eluting Stent Implantation Assessed by Optical Coherence Tomography

    Objectives We conducted this study to assess the prevalence and determinants of subclinical thrombus after sirolimus-eluting stent (SES) implantation. Background Angioscopic analyses have demonstrated the presence of thrombus is more common than the clinical incidence of SES thrombosis. Methods Fifty-three patients (53 lesions) underwent 6-month follow-up optical coherence tomography. A stent eccentricity index ([SEI] minimum/maximum stent diameter) was determined in each cross section. To evaluate unevenness of neointimal thickness, a neointimal unevenness score ([NUS] maximum neointimal thickness in the cross section/average neointimal thickness of the same cross section) was calculated for each cross section. Average SEI and NUS ...